Planning calculators for custom homes, additions and major renovations.
Maintain this server? Claim it
Call this server's tools from your browser. Nothing to install.
Requests go through mcptry because browsers can't call most MCP servers directly. Header values are sent to the server for that request only and are never stored or logged.
Tool list from our last check. Connect live to refresh it.
Ramp length for a rise at the Ontario Building Code 1 in 12 gradient, a slope check, or a doorway clear width check, using Section 3.8. Preliminary planning only. Example: /api/tools/accessible-ramp-and-doorway-calculator?mode=len&units=mm&rise=600
len = ramp length needed for a rise (needs rise); slope = check an existing slope (needs rise and run); door = doorway clear width (needs width and door)
Horizontal run (mode slope) (units)
Which doorway (mode door): path = barrier-free path of travel; suite-wide = bathroom or bedroom door in a suite served by a corridor 1,060 mm or wider; suite-narrow = same, corridor narrower than 1,060 mm
Total rise (modes len and slope) (units)
Units of rise, run and width
Clear width with the door open (mode door) (units)
Pick your client. Values in capitals, like YOUR_TOKEN, are yours to fill in.
Run in a terminal
claude mcp add --transport http tools https://andarehomes.com/mcp
Ramp length for a rise at the Ontario Building Code 1 in 12 gradient, a slope check, or a doorway clear width check, using Section 3.8. Preliminary planning only. Example: /api/tools/accessible-ramp-and-doorway-calculator?mode=len&units=mm&rise=600
| Argument | Type | Description |
|---|---|---|
| run | number | Horizontal run (mode slope) (units) |
| door | string | Which doorway (mode door): path = barrier-free path of travel; suite-wide = bathroom or bedroom door in a suite served by a corridor 1,060 mm or wider; suite-narrow = same, corridor narrower than 1,060 mm |
| mode* | string | len = ramp length needed for a rise (needs rise); slope = check an existing slope (needs rise and run); door = doorway clear width (needs width and door) |
| rise | number | Total rise (modes len and slope) (units) |
| units | string | Units of rise, run and width |
| width | number | Clear width with the door open (mode door) (units) |
{
"type": "object",
"required": [
"mode"
],
"properties": {
"run": {
"type": "number",
"description": "Horizontal run (mode slope) (units)"
},
"door": {
"enum": [
"path",
"suite-wide",
"suite-narrow"
],
"type": "string",
"description": "Which doorway (mode door): path = barrier-free path of travel; suite-wide = bathroom or bedroom door in a suite served by a corridor 1,060 mm or wider; suite-narrow = same, corridor narrower than 1,060 mm"
},
"mode": {
"enum": [
"len",
"slope",
"door"
],
"type": "string",
"description": "len = ramp length needed for a rise (needs rise); slope = check an existing slope (needs rise and run); door = doorway clear width (needs width and door)"
},
"rise": {
"type": "number",
"description": "Total rise (modes len and slope) (units)"
},
"units": {
"enum": [
"mm",
"in"
],
"type": "string",
"description": "Units of rise, run and width"
},
"width": {
"type": "number",
"description": "Clear width with the door open (mode door) (units)"
}
}
}Tests basement ceiling height, height under beams and ducts, and stair headroom against Ontario Building Code Part 9, for a house basement or a secondary suite. Window sizes are tested by the egress window size calculator. Preliminary planning only. Example: /api/tools/basement-ceiling-height-and-egress-checker?units=mm&type=suite&ceiling=2000&obstruction=1900&stair=1980
| Argument | Type | Description |
|---|---|---|
| type* | string | house = basement of a house without a secondary suite; suite = secondary suite |
| share | number | house only: percent of the basement floor area with a ceiling of 2,100 mm or more (default 100 when the ceiling is 2,100 mm or more, otherwise 0) (%) |
| stair | number | Clear height over the basement stair, measured from the line through the tread nosings (units) |
| units | string | Units of every height |
| bedroom | string | house only: a bedroom is planned in the basement |
| ceiling* | number | Finished ceiling height over the main part of the space, floor to underside of the finished ceiling (units) |
| bedroom_low | number | house with bedroom only: lowest ceiling in the bedroom (units) |
| obstruction | number | Lowest clear height under a beam or duct (units) |
| bedroom_share | number | house with bedroom only: percent of the required bedroom floor area with a ceiling of 2,300 mm or more (%) |
{
"type": "object",
"required": [
"type",
"ceiling"
],
"properties": {
"type": {
"enum": [
"house",
"suite"
],
"type": "string",
"description": "house = basement of a house without a secondary suite; suite = secondary suite"
},
"share": {
"type": "number",
"description": "house only: percent of the basement floor area with a ceiling of 2,100 mm or more (default 100 when the ceiling is 2,100 mm or more, otherwise 0) (%)"
},
"stair": {
"type": "number",
"description": "Clear height over the basement stair, measured from the line through the tread nosings (units)"
},
"units": {
"enum": [
"mm",
"in"
],
"type": "string",
"description": "Units of every height"
},
"bedroom": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "house only: a bedroom is planned in the basement"
},
"ceiling": {
"type": "number",
"description": "Finished ceiling height over the main part of the space, floor to underside of the finished ceiling (units)"
},
"bedroom_low": {
"type": "number",
"description": "house with bedroom only: lowest ceiling in the bedroom (units)"
},
"obstruction": {
"type": "number",
"description": "Lowest clear height under a beam or duct (units)"
},
"bedroom_share": {
"type": "number",
"description": "house with bedroom only: percent of the required bedroom floor area with a ceiling of 2,300 mm or more (%)"
}
}
}Minimum bathroom exhaust fan rating in CFM from room size, ceiling height and fixtures, using the Home Ventilating Institute guidance. Preliminary planning only. Example: /api/tools/bathroom-exhaust-fan-calculator?units=ft&length=8&width=10&height=8
| Argument | Type | Description |
|---|---|---|
| units | string | Units of length, width and height |
| width* | number | Room width (units) |
| height | number | Ceiling height (units) |
| length* | number | Room length (units) |
| fixtures | string | Comma separated fixtures in the room; needed only when the room is over 100 sq ft |
{
"type": "object",
"required": [
"length",
"width"
],
"properties": {
"units": {
"enum": [
"ft",
"m"
],
"type": "string",
"description": "Units of length, width and height"
},
"width": {
"type": "number",
"description": "Room width (units)"
},
"height": {
"type": "number",
"description": "Ceiling height (units)"
},
"length": {
"type": "number",
"description": "Room length (units)"
},
"fixtures": {
"type": "string",
"description": "Comma separated fixtures in the room; needed only when the room is over 100 sq ft"
}
}
}Says whether a deck in Toronto needs a building permit, whether a guard is required, the minimum guard height, opening size and stair handrail rule, from the City of Toronto and Ontario Building Code Part 9. Preliminary planning only. Example: /api/tools/deck-permit-and-guard-checker-toronto?units=mm&height=900&attached=yes&roofed=no&exit=no&risers=4&guard_height=900&gap=90
| Argument | Type | Description |
|---|---|---|
| gap | number | Planned clear opening between pickets or balusters (units) |
| exit* | string | The deck forms part of an exit required under the Building Code |
| units | string | Units of height, guard height and gap |
| height* | number | Height of the finished deck surface above the adjacent finished grade (units) |
| risers | number | Number of risers on the deck stairs (whole number) |
| roofed* | string | The deck has a roof |
| attached* | string | The deck is attached to the house |
| guard_height | number | Planned guard height (units) |
{
"type": "object",
"required": [
"height",
"attached",
"roofed",
"exit"
],
"properties": {
"gap": {
"type": "number",
"description": "Planned clear opening between pickets or balusters (units)"
},
"exit": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "The deck forms part of an exit required under the Building Code"
},
"units": {
"enum": [
"mm",
"in"
],
"type": "string",
"description": "Units of height, guard height and gap"
},
"height": {
"type": "number",
"description": "Height of the finished deck surface above the adjacent finished grade (units)"
},
"risers": {
"type": "number",
"description": "Number of risers on the deck stairs (whole number)"
},
"roofed": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "The deck has a roof"
},
"attached": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "The deck is attached to the house"
},
"guard_height": {
"type": "number",
"description": "Planned guard height (units)"
}
}
}Tests a bedroom escape window against Ontario Building Code Article 9.9.10.1: open area of at least 0.35 m2, no dimension under 380 mm, sill height and window well clearance. Preliminary planning only. Example: /api/tools/egress-window-size-calculator?units=mm&type=casement&width=600&height=700&floor=basement&well=yes&well_clearance=600
| Argument | Type | Description |
|---|---|---|
| sill | number | Sill height above the floor (tested only when floor is above) (units) |
| type* | string | Window type |
| well | string | The window opens into a window well |
| floor* | string | basement = window in a basement area; above = any other floor |
| units | string | Units of width, height, sill and clearance |
| width* | number | Clear width of the unobstructed open portion with the window fully open (units) |
| height* | number | Clear height of the unobstructed open portion with the window fully open (units) |
| well_clearance | number | Clearance in front of the window inside the well (units) |
{
"type": "object",
"required": [
"type",
"width",
"height",
"floor"
],
"properties": {
"sill": {
"type": "number",
"description": "Sill height above the floor (tested only when floor is above) (units)"
},
"type": {
"enum": [
"casement",
"awning",
"single-hung",
"double-hung",
"sliding",
"hopper",
"other"
],
"type": "string",
"description": "Window type"
},
"well": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "The window opens into a window well"
},
"floor": {
"enum": [
"basement",
"above"
],
"type": "string",
"description": "basement = window in a basement area; above = any other floor"
},
"units": {
"enum": [
"mm",
"in"
],
"type": "string",
"description": "Units of width, height, sill and clearance"
},
"width": {
"type": "number",
"description": "Clear width of the unobstructed open portion with the window fully open (units)"
},
"height": {
"type": "number",
"description": "Clear height of the unobstructed open portion with the window fully open (units)"
},
"well_clearance": {
"type": "number",
"description": "Clearance in front of the window inside the well (units)"
}
}
}Checks height, separation, floor area, setbacks and lot coverage of a garden suite against Toronto By-law 849-2025. Preliminary planning only. Example: /api/tools/garden-suite-zoning-checker?zone=yes&laneway=no&lot_area=400&lot_depth=40&lot_frontage=10&house_gfa=180&house_footprint=90&ancillary_footprint=40&suite_height=4&separation=5&suite_gfa=50&rear_setback=2&side_setback=1.5&one_storey=yes&rear_openings=no&side_openings=yes
| Argument | Type | Description |
|---|---|---|
| zone* | string | Property is in a residential zone (R, RD, RS, RT, RM) |
| laneway* | string | Property abuts a public laneway |
| lot_area* | number | Lot area (m2) |
| house_gfa* | number | House gross floor area, all floors (m2) |
| lot_depth* | number | Lot depth (m) |
| suite_gfa* | number | Suite gross floor area, all floors including a basement (m2) |
| one_storey* | string | Suite is one storey |
| separation* | number | Distance from the main wall of the house (m) |
| lot_frontage* | number | Lot frontage (m) |
| rear_setback* | number | Rear yard setback (m) |
| side_setback* | number | Smallest side yard setback (m) |
| suite_height* | number | Suite height from average grade (m) |
| rear_openings* | string | Rear lot line abuts a residential-zone lot and the rear wall has openings more than 4.0 m above grade |
| side_openings* | string | Side wall facing a side lot line (not a street) has doors or windows |
| house_footprint* | number | House footprint (m2) |
| ancillary_footprint* | number | Footprint of all ancillary buildings together, including the suite (m2) |
{
"type": "object",
"required": [
"zone",
"laneway",
"lot_area",
"lot_depth",
"lot_frontage",
"house_gfa",
"house_footprint",
"ancillary_footprint",
"suite_height",
"separation",
"suite_gfa",
"rear_setback",
"side_setback",
"one_storey",
"rear_openings",
"side_openings"
],
"properties": {
"zone": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "Property is in a residential zone (R, RD, RS, RT, RM)"
},
"laneway": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Property abuts a public laneway"
},
"lot_area": {
"type": "number",
"description": "Lot area (m2)"
},
"house_gfa": {
"type": "number",
"description": "House gross floor area, all floors (m2)"
},
"lot_depth": {
"type": "number",
"description": "Lot depth (m)"
},
"suite_gfa": {
"type": "number",
"description": "Suite gross floor area, all floors including a basement (m2)"
},
"one_storey": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Suite is one storey"
},
"separation": {
"type": "number",
"description": "Distance from the main wall of the house (m)"
},
"lot_frontage": {
"type": "number",
"description": "Lot frontage (m)"
},
"rear_setback": {
"type": "number",
"description": "Rear yard setback (m)"
},
"side_setback": {
"type": "number",
"description": "Smallest side yard setback (m)"
},
"suite_height": {
"type": "number",
"description": "Suite height from average grade (m)"
},
"rear_openings": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Rear lot line abuts a residential-zone lot and the rear wall has openings more than 4.0 m above grade"
},
"side_openings": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Side wall facing a side lot line (not a street) has doors or windows"
},
"house_footprint": {
"type": "number",
"description": "House footprint (m2)"
},
"ancillary_footprint": {
"type": "number",
"description": "Footprint of all ancillary buildings together, including the suite (m2)"
}
}
}How much paint, how many drywall sheets or how many boxes of flooring a rectangular room needs, with an adjustable waste allowance. Quantities only. Preliminary planning only. Example: /api/tools/renovation-materials-calculator?material=paint&units=ft&length=12&width=10&height=8&openings=40&coats=2&coverage=350
| Argument | Type | Description |
|---|---|---|
| coats | number | Number of coats (paint) |
| sheet | string | Drywall sheet length in feet, 4 ft wide (drywall) |
| units | string | ft = feet, sq ft and gallons; m = metres, m2 and litres |
| waste | number | Waste allowance in percent (drywall and floor) (%) |
| width* | number | Room width (units) |
| height | number | Ceiling height (paint and drywall) (units) |
| length* | number | Room length (units) |
| ceiling | string | Include the ceiling (paint and drywall) |
| coverage | number | Coverage printed on the paint can (paint) (sq ft per gallon or m2 per litre) |
| material* | string | What to calculate |
| openings | number | Doors and windows to subtract (paint and drywall) (area in sq ft or m2) |
| box_coverage | number | Coverage printed on one box of flooring (floor) (sq ft or m2) |
{
"type": "object",
"required": [
"material",
"length",
"width"
],
"properties": {
"coats": {
"type": "number",
"description": "Number of coats (paint)"
},
"sheet": {
"enum": [
"8",
"10",
"12"
],
"type": "string",
"description": "Drywall sheet length in feet, 4 ft wide (drywall)"
},
"units": {
"enum": [
"ft",
"m"
],
"type": "string",
"description": "ft = feet, sq ft and gallons; m = metres, m2 and litres"
},
"waste": {
"type": "number",
"description": "Waste allowance in percent (drywall and floor) (%)"
},
"width": {
"type": "number",
"description": "Room width (units)"
},
"height": {
"type": "number",
"description": "Ceiling height (paint and drywall) (units)"
},
"length": {
"type": "number",
"description": "Room length (units)"
},
"ceiling": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Include the ceiling (paint and drywall)"
},
"coverage": {
"type": "number",
"description": "Coverage printed on the paint can (paint) (sq ft per gallon or m2 per litre)"
},
"material": {
"enum": [
"paint",
"drywall",
"floor"
],
"type": "string",
"description": "What to calculate"
},
"openings": {
"type": "number",
"description": "Doors and windows to subtract (paint and drywall) (area in sq ft or m2)"
},
"box_coverage": {
"type": "number",
"description": "Coverage printed on one box of flooring (floor) (sq ft or m2)"
}
}
}A checklist of Ontario Building Code, Planning Act, Fire Code and City of Toronto items to check before adding a secondary suite to a house, each with its section number. Preliminary planning only. Example: /api/tools/second-suite-requirements-checklist?building=detached&smaller=yes&units_now=1&location=basement&fuel=yes&parking=one&rental=yes
| Argument | Type | Description |
|---|---|---|
| fuel* | string | A fuel-burning appliance, flue, fireplace or attached garage is in or next to the suite |
| rental* | string | The suite will be rented |
| parking* | string | Parking spaces available for the suite |
| smaller* | string | The new unit will be smaller than the main unit |
| building* | string | Existing building type |
| location* | string | Where the suite will be |
| units_now* | string | Dwelling units in the house now |
{
"type": "object",
"required": [
"building",
"smaller",
"units_now",
"location",
"fuel",
"parking",
"rental"
],
"properties": {
"fuel": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "A fuel-burning appliance, flue, fireplace or attached garage is in or next to the suite"
},
"rental": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "The suite will be rented"
},
"parking": {
"enum": [
"none",
"one",
"more"
],
"type": "string",
"description": "Parking spaces available for the suite"
},
"smaller": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "The new unit will be smaller than the main unit"
},
"building": {
"enum": [
"detached",
"semi",
"row",
"other"
],
"type": "string",
"description": "Existing building type"
},
"location": {
"enum": [
"basement",
"above",
"addition"
],
"type": "string",
"description": "Where the suite will be"
},
"units_now": {
"enum": [
"1",
"2"
],
"type": "string",
"description": "Dwelling units in the house now"
}
}
}Gives the number of risers allowed for a total rise, the rise and run of each option, and tests headroom and width against Ontario Building Code Part 9 Section 9.8. Preliminary planning only. Example: /api/tools/stair-calculator-ontario?units=mm&type=private&rise=2600&run=3500&headroom=1980&width=900
| Argument | Type | Description |
|---|---|---|
| run | number | Total horizontal run available (units) |
| rise* | number | Total rise from finished floor to finished floor (units) |
| type | string | private = stairs inside or outside a house or dwelling unit; public = public stairs in a residential building |
| units | string | Units of rise, run, headroom and width |
| width | number | Stair width (units) |
| headroom | number | Clear height over the stair (units) |
{
"type": "object",
"required": [
"rise"
],
"properties": {
"run": {
"type": "number",
"description": "Total horizontal run available (units)"
},
"rise": {
"type": "number",
"description": "Total rise from finished floor to finished floor (units)"
},
"type": {
"enum": [
"private",
"public"
],
"type": "string",
"description": "private = stairs inside or outside a house or dwelling unit; public = public stairs in a residential building"
},
"units": {
"enum": [
"mm",
"in"
],
"type": "string",
"description": "Units of rise, run, headroom and width"
},
"width": {
"type": "number",
"description": "Stair width (units)"
},
"headroom": {
"type": "number",
"description": "Clear height over the stair (units)"
}
}
}Says whether a project in Toronto needs a building permit, usually does not, or depends, with the City source for the answer. Preliminary planning only. Example: /api/tools/toronto-building-permit-checker?project=deck&h=high&att=yes&exit=no
| Argument | Type | Description |
|---|---|---|
| h | string | deck: How high will the finished deck level be above the adjacent finished grade? |
| bt | string | opening: What kind of building is it? |
| ht | string | fence: How tall will it be? |
| lb | string | wall: Is the wall load bearing? |
| att | string | deck: Will the deck be attached to the house? | shed: Will it be attached to a house, garage or any other structure? |
| chg | string | opening: Will the work affect the structural support or create a new exit? |
| exit | string | deck: Will it have a roof, or will it be part of a required exit from the house? |
| kind | string | opening: What is the work? | plumbing: What is the plumbing work? |
| mech | string | basement: Will it include new plumbing or heating work? |
| pool | string | fence: Is the fence a swimming pool enclosure? |
| size | string | shed: What is the gross floor area? |
| plumb | string | kitchen: Will you add or move plumbing, such as relocating a sink, shower, tub, toilet or drain? | shed: Will it have plumbing? |
| scope | string | kitchen: Is the work limited to replacing cabinets, counters, finishes and fixtures in the same locations? |
| suite | string | basement: Will the work create a second suite or any additional dwelling unit? |
| walls | string | kitchen: Will you add or remove any walls or change any openings? |
| where | string | fence: Where will the fence be? |
| struct | string | basement: Will it include structural or material alterations, such as adding or removing walls, excavation, underpinning or a new basement entrance? | roofing: Will the work include any structural repair, such as replacing rafters, trusses or framing, or changing the roof shape? |
| project* | string | What is being built |
{
"type": "object",
"required": [
"project"
],
"properties": {
"h": {
"enum": [
"low",
"high",
"unsure"
],
"type": "string",
"description": "deck: How high will the finished deck level be above the adjacent finished grade?"
},
"bt": {
"enum": [
"house",
"other"
],
"type": "string",
"description": "opening: What kind of building is it?"
},
"ht": {
"enum": [
"t12",
"t20",
"over"
],
"type": "string",
"description": "fence: How tall will it be?"
},
"lb": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "wall: Is the wall load bearing?"
},
"att": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "deck: Will the deck be attached to the house? | shed: Will it be attached to a house, garage or any other structure?"
},
"chg": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "opening: Will the work affect the structural support or create a new exit?"
},
"exit": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "deck: Will it have a roof, or will it be part of a required exit from the house?"
},
"kind": {
"enum": [
"new",
"repl",
"add",
"valve"
],
"type": "string",
"description": "opening: What is the work? | plumbing: What is the plumbing work?"
},
"mech": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "basement: Will it include new plumbing or heating work?"
},
"pool": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "fence: Is the fence a swimming pool enclosure?"
},
"size": {
"enum": [
"small",
"exact",
"big"
],
"type": "string",
"description": "shed: What is the gross floor area?"
},
"plumb": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "kitchen: Will you add or move plumbing, such as relocating a sink, shower, tub, toilet or drain? | shed: Will it have plumbing?"
},
"scope": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "kitchen: Is the work limited to replacing cabinets, counters, finishes and fixtures in the same locations?"
},
"suite": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "basement: Will the work create a second suite or any additional dwelling unit?"
},
"walls": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "kitchen: Will you add or remove any walls or change any openings?"
},
"where": {
"enum": [
"front",
"other"
],
"type": "string",
"description": "fence: Where will the fence be?"
},
"struct": {
"enum": [
"yes",
"no",
"unsure"
],
"type": "string",
"description": "basement: Will it include structural or material alterations, such as adding or removing walls, excavation, underpinning or a new basement entrance? | roofing: Will the work include any structural repair, such as replacing rafters, trusses or framing, or changing the roof shape?"
},
"project": {
"enum": [
"basement",
"deck",
"wall",
"opening",
"kitchen",
"plumbing",
"shed",
"roofing",
"fence"
],
"type": "string",
"description": "What is being built"
}
}
}Gives the last day of the City of Toronto published review time for a complete building permit application, by review stream. Preliminary planning only. Example: /api/tools/toronto-permit-review-time-calculator?stream=house&date=2026-12-01&zoning_certificate=yes
| Argument | Type | Description |
|---|---|---|
| date* | string | Date the complete application is taken in (YYYY-MM-DD) |
| stream* | string | Review stream: house = House Stream (10 business days); small = Small Building Stream (15); large = Large and Complex, large building (20); complex = Large and Complex, complex building (30); express = Express Services (goal of 3) |
| zoning_certificate* | string | Application includes an issued Zoning Applicable Law Certificate and all fees paid |
{
"type": "object",
"required": [
"stream",
"date",
"zoning_certificate"
],
"properties": {
"date": {
"type": "string",
"description": "Date the complete application is taken in (YYYY-MM-DD)"
},
"stream": {
"enum": [
"house",
"small",
"large",
"complex",
"express"
],
"type": "string",
"description": "Review stream: house = House Stream (10 business days); small = Small Building Stream (15); large = Large and Complex, large building (20); complex = Large and Complex, complex building (30); express = Express Services (goal of 3)"
},
"zoning_certificate": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Application includes an issued Zoning Applicable Law Certificate and all fees paid"
}
}
}We read every tool's name, description and inputs the way the model will, looking for instructions hidden from you. A clean result means no warning signs, not a guarantee. Scanned Nov 16, 2026.