Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. This does not certify a washroom.
stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom.
Stall door swing.
Universal washroom internal width. Unit: mm.
Universal washroom internal length. Unit: mm.
Stall only: water closet seat height above the floor. Unit: mm.
Stall clear depth (stall and ambulatory). Unit: mm.
Stall clear width (stall and ambulatory). Unit: mm.
Universal washroom: latch height above the floor. Unit: mm.
Universal washroom: power door operator fitted.
Universal washroom: diameter of open turning space. Unit: mm.
Stall only: water closet centre line to the nearest side wall. Unit: mm.
Door clear opening with the door open (all types). Unit: mm.
Stall with inward washroom door: clearance from stall face to that door. Unit: mm.
Lavatory rim height above the floor. Unit: mm.
Stall only: diameter of clear floor space in front of the stall. Unit: mm.
Stall only: clear transfer space depth beside the water closet. Unit: mm.
Stall only: clear transfer space width beside the water closet. Unit: mm.
Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing?
Clearance under the lavatory at the front edge. Unit: mm.
Universal washroom: clear space width for an adult change table. Unit: mm.
Universal washroom: clear space length for an adult change table. Unit: mm.
Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm.
Pick your client. Values in capitals, like YOUR_TOKEN, are yours to fill in.
Run in a terminal
claude mcp add --transport http tools https://ardenvaleconstruction.com/mcp
Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. This does not certify a washroom.
| Argument | Type | Description |
|---|---|---|
| type | string | stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom. |
| door_swing | string | Stall door swing. |
| room_width_mm | number | Universal washroom internal width. Unit: mm. |
| room_length_mm | number | Universal washroom internal length. Unit: mm. |
| seat_height_mm | number | Stall only: water closet seat height above the floor. Unit: mm. |
| stall_depth_mm | number | Stall clear depth (stall and ambulatory). Unit: mm. |
| stall_width_mm | number | Stall clear width (stall and ambulatory). Unit: mm. |
| latch_height_mm | number | Universal washroom: latch height above the floor. Unit: mm. |
| power_door_operator | boolean | Universal washroom: power door operator fitted. |
| turning_diameter_mm | number | Universal washroom: diameter of open turning space. Unit: mm. |
| wc_centre_to_wall_mm | number | Stall only: water closet centre line to the nearest side wall. Unit: mm. |
| door_clear_opening_mm | number | Door clear opening with the door open (all types). Unit: mm. |
| stall_face_to_door_mm | number | Stall with inward washroom door: clearance from stall face to that door. Unit: mm. |
| lavatory_rim_height_mm | number | Lavatory rim height above the floor. Unit: mm. |
| front_clear_diameter_mm | number | Stall only: diameter of clear floor space in front of the stall. Unit: mm. |
| transfer_space_depth_mm | number | Stall only: clear transfer space depth beside the water closet. Unit: mm. |
| transfer_space_width_mm | number | Stall only: clear transfer space width beside the water closet. Unit: mm. |
| inward_door_clear_area_ok | boolean | Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing? |
| lavatory_knee_clearance_mm | number | Clearance under the lavatory at the front edge. Unit: mm. |
| change_table_space_width_mm | number | Universal washroom: clear space width for an adult change table. Unit: mm. |
| change_table_space_length_mm | number | Universal washroom: clear space length for an adult change table. Unit: mm. |
| stall_face_to_obstruction_mm | number | Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm. |
{
"type": "object",
"required": [],
"properties": {
"type": {
"enum": [
"stall",
"ambulatory",
"universal"
],
"type": "string",
"default": "stall",
"description": "stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom."
},
"door_swing": {
"enum": [
"outward",
"inward"
],
"type": "string",
"description": "Stall door swing."
},
"room_width_mm": {
"type": "number",
"description": "Universal washroom internal width. Unit: mm."
},
"room_length_mm": {
"type": "number",
"description": "Universal washroom internal length. Unit: mm."
},
"seat_height_mm": {
"type": "number",
"description": "Stall only: water closet seat height above the floor. Unit: mm."
},
"stall_depth_mm": {
"type": "number",
"description": "Stall clear depth (stall and ambulatory). Unit: mm."
},
"stall_width_mm": {
"type": "number",
"description": "Stall clear width (stall and ambulatory). Unit: mm."
},
"latch_height_mm": {
"type": "number",
"description": "Universal washroom: latch height above the floor. Unit: mm."
},
"power_door_operator": {
"type": "boolean",
"description": "Universal washroom: power door operator fitted."
},
"turning_diameter_mm": {
"type": "number",
"description": "Universal washroom: diameter of open turning space. Unit: mm."
},
"wc_centre_to_wall_mm": {
"type": "number",
"description": "Stall only: water closet centre line to the nearest side wall. Unit: mm."
},
"door_clear_opening_mm": {
"type": "number",
"description": "Door clear opening with the door open (all types). Unit: mm."
},
"stall_face_to_door_mm": {
"type": "number",
"description": "Stall with inward washroom door: clearance from stall face to that door. Unit: mm."
},
"lavatory_rim_height_mm": {
"type": "number",
"description": "Lavatory rim height above the floor. Unit: mm."
},
"front_clear_diameter_mm": {
"type": "number",
"description": "Stall only: diameter of clear floor space in front of the stall. Unit: mm."
},
"transfer_space_depth_mm": {
"type": "number",
"description": "Stall only: clear transfer space depth beside the water closet. Unit: mm."
},
"transfer_space_width_mm": {
"type": "number",
"description": "Stall only: clear transfer space width beside the water closet. Unit: mm."
},
"inward_door_clear_area_ok": {
"type": "boolean",
"description": "Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing?"
},
"lavatory_knee_clearance_mm": {
"type": "number",
"description": "Clearance under the lavatory at the front edge. Unit: mm."
},
"change_table_space_width_mm": {
"type": "number",
"description": "Universal washroom: clear space width for an adult change table. Unit: mm."
},
"change_table_space_length_mm": {
"type": "number",
"description": "Universal washroom: clear space length for an adult change table. Unit: mm."
},
"stall_face_to_obstruction_mm": {
"type": "number",
"description": "Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm."
}
}
}Check indoor play space, outdoor play space and sleeping area per child for an Ontario licensed child care centre. Preliminary planning check only. Licensing is decided by the ministry. The architect, the engineer and the permit set govern the design.
| Argument | Type | Description |
|---|---|---|
| unit | string | Area unit for every area value. |
| groups* | string | Required. Licensed age groups as group:children:floor_area, comma separated, for example preschool:24:70,infant:10:25. |
| six_hours | boolean | Program runs six hours or more in a day. |
| outdoor_area | number | Outdoor play space available. 0 shows only the requirement. Unit: unit. |
| sleeping_area | number | Sleeping area available. Unit: unit. |
| sleeping_children | integer | Children sleeping at one time. Unit: children. |
{
"type": "object",
"required": [
"groups"
],
"properties": {
"unit": {
"enum": [
"m2",
"ft2"
],
"type": "string",
"default": "m2",
"description": "Area unit for every area value."
},
"groups": {
"type": "string",
"description": "Required. Licensed age groups as group:children:floor_area, comma separated, for example preschool:24:70,infant:10:25."
},
"six_hours": {
"type": "boolean",
"default": true,
"description": "Program runs six hours or more in a day."
},
"outdoor_area": {
"type": "number",
"default": 0,
"description": "Outdoor play space available. 0 shows only the requirement. Unit: unit."
},
"sleeping_area": {
"type": "number",
"default": 0,
"description": "Sleeping area available. Unit: unit."
},
"sleeping_children": {
"type": "integer",
"default": 0,
"description": "Children sleeping at one time. Unit: children."
}
}
}Required exit width, number of exits, door count and travel distance limit for an occupant load under Ontario Building Code Subsections 3.4.2 and 3.4.3. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the means of egress.
| Argument | Type | Description |
|---|---|---|
| group | string | Major occupancy of the floor area. |
| element | string | Exit element to size in the headline answer. |
| storeys | integer | Building height in storeys. Unit: storeys. |
| sprinklered | boolean | Floor area sprinklered throughout. |
| floor_area_m2 | number | Floor area, to test the one-exit option. Unit: m2. |
| occupant_load* | integer | Occupant load of the floor area served (required). Use the occupant load calculator for the table value. Unit: persons. |
| max_diagonal_m | number | Maximum diagonal dimension of the floor area, to find the least distance between two exits. Unit: m. |
| travel_distance_m | number | Longest travel distance from any point to an exit, measured along the path of travel. Unit: m. |
| door_clear_width_mm | number | Clear opening of one door leaf you plan to use, 850 mm or more. Unit: mm. |
| stairs_storeys_served | integer | Storeys the exit stair serves above the lowest exit level. Over 2 sets the 1,100 mm minimum stair width. Unit: storeys. |
{
"type": "object",
"required": [
"occupant_load"
],
"properties": {
"group": {
"enum": [
"assembly",
"residential",
"business",
"mercantile",
"industrial-low",
"industrial-medium",
"industrial-high",
"care"
],
"type": "string",
"default": "mercantile",
"description": "Major occupancy of the floor area."
},
"element": {
"enum": [
"doorway",
"corridor",
"ramp",
"ramp-steep",
"stair",
"stair-other"
],
"type": "string",
"default": "doorway",
"description": "Exit element to size in the headline answer."
},
"storeys": {
"type": "integer",
"default": 1,
"description": "Building height in storeys. Unit: storeys."
},
"sprinklered": {
"type": "boolean",
"default": false,
"description": "Floor area sprinklered throughout."
},
"floor_area_m2": {
"type": "number",
"description": "Floor area, to test the one-exit option. Unit: m2."
},
"occupant_load": {
"type": "integer",
"description": "Occupant load of the floor area served (required). Use the occupant load calculator for the table value. Unit: persons."
},
"max_diagonal_m": {
"type": "number",
"description": "Maximum diagonal dimension of the floor area, to find the least distance between two exits. Unit: m."
},
"travel_distance_m": {
"type": "number",
"description": "Longest travel distance from any point to an exit, measured along the path of travel. Unit: m."
},
"door_clear_width_mm": {
"type": "number",
"default": 850,
"description": "Clear opening of one door leaf you plan to use, 850 mm or more. Unit: mm."
},
"stairs_storeys_served": {
"type": "integer",
"default": 2,
"description": "Storeys the exit stair serves above the lowest exit level. Over 2 sets the 1,100 mm minimum stair width. Unit: storeys."
}
}
}Minimum design occupant load for a floor area from Ontario Building Code Table 3.1.17.1 area per person values. Preliminary planning figure only. The architect, the engineer and the permit set govern the occupant load used for design and approval.
| Argument | Type | Description |
|---|---|---|
| use* | string | Use of the floor area (required). One slug, or several separated by commas to match area. |
| area* | number | Floor area for each use (required). Comma separated when several uses are given. Unit: unit. |
| unit | string | Area unit. |
{
"type": "object",
"required": [
"use",
"area"
],
"properties": {
"use": {
"type": "string",
"description": "Use of the floor area (required). One slug, or several separated by commas to match area."
},
"area": {
"type": "number",
"description": "Floor area for each use (required). Comma separated when several uses are given. Unit: unit."
},
"unit": {
"enum": [
"m2",
"ft2"
],
"type": "string",
"default": "m2",
"description": "Area unit."
}
}
}Estimate usable and rentable office square feet from headcount, growth, desk sharing, rooms, circulation and load factor. Preliminary planning estimate only. The architect's test fit, the building drawings and the permit set govern the actual layout.
| Argument | Type | Description |
|---|---|---|
| pattern | string | Work pattern. Sets the default desk sharing ratio. |
| employees* | integer | Employees now (required). Unit: people. |
| reception | boolean | Include a reception area. |
| growth_pct | number | Expected growth over the lease term. Unit: percent. |
| kitchen_sqft | number | Kitchen and break area. 0 for none. Unit: sq ft. |
| storage_room | boolean | Include a storage or server room. |
| circulation_pct | number | Circulation allowance added to the components. Unit: percent. |
| load_factor_pct | number | Load factor: rentable = usable x (1 + load factor). Unit: percent. |
| people_per_desk | number | Desk sharing ratio, 1 or more. Default follows pattern: office 1, hybrid 1.5, remote 3. Unit: people per desk. |
| private_offices | integer | Private offices. Unit: count. |
| area_storage_sqft | number | Storage or server room area. Unit: sq ft. |
| area_reception_sqft | number | Reception area. Unit: sq ft. |
| large_meeting_rooms | integer | Large meeting rooms (12 or more people). Unit: count. |
| small_meeting_rooms | integer | Small meeting rooms (up to 4 people). Unit: count. |
| medium_meeting_rooms | integer | Medium meeting rooms (up to 8 people). Unit: count. |
| area_workstation_sqft | number | Area per workstation. Unit: sq ft each. |
| area_large_meeting_sqft | number | Area per large meeting room. Unit: sq ft each. |
| area_small_meeting_sqft | number | Area per small meeting room. Unit: sq ft each. |
| area_medium_meeting_sqft | number | Area per medium meeting room. Unit: sq ft each. |
| area_private_office_sqft | number | Area per private office. Unit: sq ft each. |
{
"type": "object",
"required": [
"employees"
],
"properties": {
"pattern": {
"enum": [
"office",
"hybrid",
"remote"
],
"type": "string",
"default": "hybrid",
"description": "Work pattern. Sets the default desk sharing ratio."
},
"employees": {
"type": "integer",
"description": "Employees now (required). Unit: people."
},
"reception": {
"type": "boolean",
"default": true,
"description": "Include a reception area."
},
"growth_pct": {
"type": "number",
"default": 20,
"description": "Expected growth over the lease term. Unit: percent."
},
"kitchen_sqft": {
"type": "number",
"default": 300,
"description": "Kitchen and break area. 0 for none. Unit: sq ft."
},
"storage_room": {
"type": "boolean",
"default": true,
"description": "Include a storage or server room."
},
"circulation_pct": {
"type": "number",
"default": 25,
"description": "Circulation allowance added to the components. Unit: percent."
},
"load_factor_pct": {
"type": "number",
"default": 15,
"description": "Load factor: rentable = usable x (1 + load factor). Unit: percent."
},
"people_per_desk": {
"type": "number",
"description": "Desk sharing ratio, 1 or more. Default follows pattern: office 1, hybrid 1.5, remote 3. Unit: people per desk."
},
"private_offices": {
"type": "integer",
"default": 4,
"description": "Private offices. Unit: count."
},
"area_storage_sqft": {
"type": "number",
"default": 120,
"description": "Storage or server room area. Unit: sq ft."
},
"area_reception_sqft": {
"type": "number",
"default": 200,
"description": "Reception area. Unit: sq ft."
},
"large_meeting_rooms": {
"type": "integer",
"default": 1,
"description": "Large meeting rooms (12 or more people). Unit: count."
},
"small_meeting_rooms": {
"type": "integer",
"default": 2,
"description": "Small meeting rooms (up to 4 people). Unit: count."
},
"medium_meeting_rooms": {
"type": "integer",
"default": 1,
"description": "Medium meeting rooms (up to 8 people). Unit: count."
},
"area_workstation_sqft": {
"type": "number",
"default": 45,
"description": "Area per workstation. Unit: sq ft each."
},
"area_large_meeting_sqft": {
"type": "number",
"default": 350,
"description": "Area per large meeting room. Unit: sq ft each."
},
"area_small_meeting_sqft": {
"type": "number",
"default": 110,
"description": "Area per small meeting room. Unit: sq ft each."
},
"area_medium_meeting_sqft": {
"type": "number",
"default": 200,
"description": "Area per medium meeting room. Unit: sq ft each."
},
"area_private_office_sqft": {
"type": "number",
"default": 150,
"description": "Area per private office. Unit: sq ft each."
}
}
}Indicative parking stall count for a change of use in Toronto, Mississauga or Brampton from the zoning by-law rates, with the by-law named. Confirm with the municipality. Indicative only. Parking requirements differ by municipality, zone and site-specific exceptions. Confirm with the municipality's zoning examiner.
| Argument | Type | Description |
|---|---|---|
| use* | string | Proposed use (required). Not every use is mapped for every city. |
| city* | string | Municipality (required). Only cities whose by-law we opened are offered. |
| zone | string | Toronto: parking zone pza, pzb or other. Mississauga: parking precinct 1, 2, 3 or 4. Ignored for Brampton. |
| brampton_core | boolean | Brampton only: the property is inside the Downtown, Central Area and Hurontario/Main Corridor area (Schedule B-7), which has no minimum. |
| gross_floor_area_m2* | number | Gross floor area of the use (required). Each by-law defines its own gross floor area. Unit: m2. |
{
"type": "object",
"required": [
"city",
"use",
"gross_floor_area_m2"
],
"properties": {
"use": {
"type": "string",
"description": "Proposed use (required). Not every use is mapped for every city."
},
"city": {
"enum": [
"toronto",
"mississauga",
"brampton"
],
"type": "string",
"description": "Municipality (required). Only cities whose by-law we opened are offered."
},
"zone": {
"enum": [
"pza",
"pzb",
"other",
"1",
"2",
"3",
"4"
],
"type": "string",
"default": "other",
"description": "Toronto: parking zone pza, pzb or other. Mississauga: parking precinct 1, 2, 3 or 4. Ignored for Brampton."
},
"brampton_core": {
"type": "boolean",
"default": false,
"description": "Brampton only: the property is inside the Downtown, Central Area and Hurontario/Main Corridor area (Schedule B-7), which has no minimum."
},
"gross_floor_area_m2": {
"type": "number",
"description": "Gross floor area of the use (required). Each by-law defines its own gross floor area. Unit: m2."
}
}
}Occupant load, seat capacity and minimum patron and employee water closets and lavatories for an Ontario restaurant or bar (Building Code Table 3.7.4.3.-D, -E and -F). Preliminary planning figure only. The architect, the public health unit, the building official and the permit set govern the seat count and the fixture count.
| Argument | Type | Description |
|---|---|---|
| seats | integer | Seats planned. 0 to use the occupant load from the area. The occupant load is the larger of the two. Unit: seats. |
| service | string | restaurant: a dining room or cafeteria (Table 3.7.4.3.-D). bar: an establishment used primarily for alcoholic beverages with limited or no food service (Table 3.7.4.3.-E). |
| storeys | integer | Storeys in the building (sets the minimum number of universal washrooms). Unit: storeys. |
| urinals | boolean | Use urinals for males up to the Code limit. |
| male_pct | number | Share counted as male, 0 to 100. The rest are counted as female. Unit: percent. |
| employees | integer | Employees normally present at one time, those present more than 25 percent of the working day (Sentence 3.7.4.3.(9)). Unit: people. |
| dining_area_m2* | number | Dining, beverage and cafeteria floor area open to patrons (required). Unit: m2. |
{
"type": "object",
"required": [
"dining_area_m2"
],
"properties": {
"seats": {
"type": "integer",
"default": 0,
"description": "Seats planned. 0 to use the occupant load from the area. The occupant load is the larger of the two. Unit: seats."
},
"service": {
"enum": [
"restaurant",
"bar"
],
"type": "string",
"default": "restaurant",
"description": "restaurant: a dining room or cafeteria (Table 3.7.4.3.-D). bar: an establishment used primarily for alcoholic beverages with limited or no food service (Table 3.7.4.3.-E)."
},
"storeys": {
"type": "integer",
"default": 1,
"description": "Storeys in the building (sets the minimum number of universal washrooms). Unit: storeys."
},
"urinals": {
"type": "boolean",
"default": true,
"description": "Use urinals for males up to the Code limit."
},
"male_pct": {
"type": "number",
"default": 50,
"description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent."
},
"employees": {
"type": "integer",
"default": 8,
"description": "Employees normally present at one time, those present more than 25 percent of the working day (Sentence 3.7.4.3.(9)). Unit: people."
},
"dining_area_m2": {
"type": "number",
"description": "Dining, beverage and cafeteria floor area open to patrons (required). Unit: m2."
}
}
}Occupant load, exits, aisle widths and accessible route for an Ontario retail store, with a fixture run estimate from shelving depth. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the layout and the means of egress.
| Argument | Type | Description |
|---|---|---|
| storey | string | Storey type, which sets the area per person: first (basement or first storey, 3.70 m2), upper-entrance (second storey with principal entrance from a pedestrian thoroughfare or parking area, 3.70 m2), other (5.60 m2). |
| storeys | integer | Building height in storeys. Unit: storeys. |
| sprinklered | boolean | Floor area sprinklered throughout. |
| floor_area_m2* | number | Retail floor area on the storey (required). Unit: m2. |
| store_width_m | number | Store width, to estimate the number of fixture runs. Depth is area divided by width. Unit: m. |
| aisle_width_mm | number | Clear aisle width you plan between fixtures. Unit: mm. |
| fixture_depth_mm | number | Depth of one fixture run (for example a double-sided gondola). Unit: mm. |
| travel_distance_m | number | Longest travel distance from any point to an exit. Unit: m. |
| door_clear_width_mm | number | Clear opening of one door leaf, 850 mm or more. Unit: mm. |
{
"type": "object",
"required": [
"floor_area_m2"
],
"properties": {
"storey": {
"enum": [
"first",
"upper-entrance",
"other"
],
"type": "string",
"default": "first",
"description": "Storey type, which sets the area per person: first (basement or first storey, 3.70 m2), upper-entrance (second storey with principal entrance from a pedestrian thoroughfare or parking area, 3.70 m2), other (5.60 m2)."
},
"storeys": {
"type": "integer",
"default": 1,
"description": "Building height in storeys. Unit: storeys."
},
"sprinklered": {
"type": "boolean",
"default": false,
"description": "Floor area sprinklered throughout."
},
"floor_area_m2": {
"type": "number",
"description": "Retail floor area on the storey (required). Unit: m2."
},
"store_width_m": {
"type": "number",
"description": "Store width, to estimate the number of fixture runs. Depth is area divided by width. Unit: m."
},
"aisle_width_mm": {
"type": "number",
"default": 1100,
"description": "Clear aisle width you plan between fixtures. Unit: mm."
},
"fixture_depth_mm": {
"type": "number",
"default": 600,
"description": "Depth of one fixture run (for example a double-sided gondola). Unit: mm."
},
"travel_distance_m": {
"type": "number",
"description": "Longest travel distance from any point to an exit. Unit: m."
},
"door_clear_width_mm": {
"type": "number",
"default": 850,
"description": "Clear opening of one door leaf, 850 mm or more. Unit: mm."
}
}
}Minimum water closets and lavatories for each sex in an Ontario office or retail space (Building Code Tables 3.7.4.7 and 3.7.4.8). Preliminary planning figure only. Accessible and universal washroom rules apply separately. The architect, the engineer and the permit set govern.
| Argument | Type | Description |
|---|---|---|
| type | string | Occupancy: office (Group D, Table 3.7.4.7) or retail (Group E, Table 3.7.4.8). |
| public | integer | Retail only: customers at one time. Unit: people. |
| area_m2 | number | Retail only: total area excluding basements. Unit: m2. |
| persons* | integer | Occupant load (office) or employees at one time (retail). Required. Unit: people. |
| urinals | boolean | Use urinals for males up to the Code limit. |
| male_pct | number | Share counted as male, 0 to 100. The rest are counted as female. Unit: percent. |
{
"type": "object",
"required": [
"persons"
],
"properties": {
"type": {
"enum": [
"office",
"retail"
],
"type": "string",
"default": "office",
"description": "Occupancy: office (Group D, Table 3.7.4.7) or retail (Group E, Table 3.7.4.8)."
},
"public": {
"type": "integer",
"default": 80,
"description": "Retail only: customers at one time. Unit: people."
},
"area_m2": {
"type": "number",
"default": 400,
"description": "Retail only: total area excluding basements. Unit: m2."
},
"persons": {
"type": "integer",
"description": "Occupant load (office) or employees at one time (retail). Required. Unit: people."
},
"urinals": {
"type": "boolean",
"default": true,
"description": "Use urinals for males up to the Code limit."
},
"male_pct": {
"type": "number",
"default": 50,
"description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent."
}
}
}We read every tool's name, description and inputs the way the model will, looking for instructions hidden from you. A clean result means no warning signs, not a guarantee. Scanned Nov 16, 2026.