Planning calculators for structural framing and building projects.
Maintain this server? Claim it
Call this server's tools from your browser. Nothing to install.
Requests go through mcptry because browsers can't call most MCP servers directly. Header values are sent to the server for that request only and are never stored or logged.
Tool list from our last check. Connect live to refresh it.
Maximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-A and 9.23.4.2.-H, Articles 9.4.2.3., 9.4.2.2., 9.17.1.1. and 9.17.4.1., and SB-1 Table 2.
Joist clear span in feet (or use span_m). With a ledger on the house this is the distance from the ledger to the beam. Unit: ft.
Clear span of the beam between posts, in feet (or use post_spacing_m). Unit: ft.
Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead.
Joist or rafter size (38 mm thick).
Lumber grade.
Joist clear span between the ledger or beam on each side in metres, instead of span_ft. Unit: m.
Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa.
Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa.
Extra inches added to span_ft. Unit: in.
Species group.
Joist bridging and strapping (Table 9.23.4.2.-A).
Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm.
Beam span between posts in metres, instead of post_spacing_ft. Unit: m.
Joist span on the far side of the beam, for a beam in the middle of the deck. Leave 0 for a beam at the edge. Unit: ft.
Pick your client. Values in capitals, like YOUR_TOKEN, are yours to fill in.
Run in a terminal
claude mcp add --transport http tools https://timberrframing.com/mcp
Maximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-A and 9.23.4.2.-H, Articles 9.4.2.3., 9.4.2.2., 9.17.1.1. and 9.17.4.1., and SB-1 Table 2.
| Argument | Type | Description |
|---|---|---|
| city | string | Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead. |
| size | string | Joist or rafter size (38 mm thick). |
| grade | string | Lumber grade. |
| span_m | number | Joist clear span between the ledger or beam on each side in metres, instead of span_ft. Unit: m. |
| sr_kpa | number | Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa. |
| ss_kpa | number | Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa. |
| span_ft* | number | Joist clear span in feet (or use span_m). With a ledger on the house this is the distance from the ledger to the beam. Unit: ft. |
| span_in | number | Extra inches added to span_ft. Unit: in. |
| species | string | Species group. |
| support | string | Joist bridging and strapping (Table 9.23.4.2.-A). |
| spacing_mm | integer | Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm. |
| post_spacing_m | number | Beam span between posts in metres, instead of post_spacing_ft. Unit: m. |
| post_spacing_ft* | number | Clear span of the beam between posts, in feet (or use post_spacing_m). Unit: ft. |
| other_side_span_ft | number | Joist span on the far side of the beam, for a beam in the middle of the deck. Leave 0 for a beam at the edge. Unit: ft. |
{
"type": "object",
"required": [
"span_ft",
"post_spacing_ft"
],
"properties": {
"city": {
"enum": [
"toronto",
"etobicoke",
"north-york",
"scarborough",
"mississauga",
"brampton",
"vaughan",
"markham",
"richmond-hill",
"aurora",
"newmarket",
"uxbridge",
"bradford",
"barrie",
"oakville",
"burlington",
"milton",
"caledon",
"ajax",
"whitby",
"oshawa",
"hamilton-below-escarpment",
"hamilton-above-escarpment",
"cambridge",
"guelph",
"kitchener",
"waterloo",
"bracebridge",
"gravenhurst",
"huntsville",
"collingwood",
"parry-sound"
],
"type": "string",
"description": "Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead."
},
"size": {
"enum": [
"2x4",
"2x6",
"2x8",
"2x10",
"2x12"
],
"type": "string",
"default": "2x10",
"description": "Joist or rafter size (38 mm thick)."
},
"grade": {
"enum": [
"SS",
"No1",
"No3"
],
"type": "string",
"default": "No1",
"description": "Lumber grade."
},
"span_m": {
"type": "number",
"description": "Joist clear span between the ledger or beam on each side in metres, instead of span_ft. Unit: m."
},
"sr_kpa": {
"type": "number",
"default": 0.4,
"description": "Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"ss_kpa": {
"type": "number",
"description": "Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"span_ft": {
"type": "number",
"description": "Joist clear span in feet (or use span_m). With a ledger on the house this is the distance from the ledger to the beam. Unit: ft."
},
"span_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to span_ft. Unit: in."
},
"species": {
"enum": [
"SPF",
"DFL",
"Hem-Fir",
"Northern"
],
"type": "string",
"default": "SPF",
"description": "Species group."
},
"support": {
"enum": [
"strapping",
"bridging",
"both"
],
"type": "string",
"default": "strapping",
"description": "Joist bridging and strapping (Table 9.23.4.2.-A)."
},
"spacing_mm": {
"enum": [
300,
400,
600
],
"type": "integer",
"default": 400,
"description": "Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm."
},
"post_spacing_m": {
"type": "number",
"description": "Beam span between posts in metres, instead of post_spacing_ft. Unit: m."
},
"post_spacing_ft": {
"type": "number",
"description": "Clear span of the beam between posts, in feet (or use post_spacing_m). Unit: ft."
},
"other_side_span_ft": {
"type": "number",
"default": 0,
"description": "Joist span on the far side of the beam, for a beam in the middle of the deck. Leave 0 for a beam at the edge. Unit: ft."
}
}
}Fire-resistance rating and sound rating the 2024 Ontario Building Code Part 9 requires for a wall between dwelling units: a party wall on a property line (townhouse, semi-detached), a wall between suites in one building, a house with a secondary suite, or a garage wall. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.10.8.1., 9.10.9.15., 9.10.9.16., 9.10.9.18., 9.10.11.1. to 9.10.11.4., 9.11.1.1. and 9.11.1.3., and Article 3.1.10.2. to 3.1.10.5.
| Argument | Type | Description |
|---|---|---|
| wall_use | string | What the wall separates: party-wall (dwelling units on either side of a property line, such as townhouses or semi-detached houses), suites (units in one building with no property line, such as a duplex, triplex or stacked units), secondary-suite (a house with a secondary suite), garage-garage (two attached garages across a property line), garage-dwelling (a garage and the dwelling it serves). |
| sprinklered | string | Is the house with a secondary suite sprinklered? Used for the secondary-suite case only. |
| two_storey_unit | string | Does a dwelling unit have 2 or more storeys, counting the basement? |
| unit_above_unit | string | Is any dwelling unit above another dwelling unit (stacked units)? |
| garage_serves_dwelling | string | Does the garage serve only the dwelling it is attached to? Used for garage-dwelling only. |
Maximum floor joist span for dimension lumber from Table 9.23.4.2.-A of the 2024 Ontario Building Code, and whether your clear span is within it. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-A, Maximum Spans for Floor Joists, General Cases.
| Argument | Type | Description |
|---|---|---|
| size | string | Joist or rafter size (38 mm thick). |
| grade | string | Lumber grade. |
| span_m | number | Clear span between the inside faces of the supports in metres, instead of span_ft. Unit: m. |
| span_ft* | number | Clear span between the inside faces of the supports in feet (or use span_m). Unit: ft. |
| span_in | number | Extra inches added to span_ft. Unit: in. |
| species | string | Species group. |
| support | string | Bridging and strapping. |
| spacing_mm | integer | Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm. |
Smallest sawn lumber lintel over a door or window opening in a loadbearing wall, from Tables 9.23.12.3.-A to C of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Tables 9.23.12.3.-A to 9.23.12.3.-C, Maximum Spans for Lintels (No. 1 or No. 2 grade lumber).
| Argument | Type | Description |
|---|---|---|
| wall | string | Exterior or interior wall (attic is always interior). |
| species | string | Lumber species group (No. 1 or No. 2 grade). |
| snow_kpa | number | Specified roof snow load for exterior walls; the column at or above it is used. Unit: kPa. |
| supports | string | What the lintel supports: attic (limited attic storage and ceiling), roof (roof and ceiling, tributary width 0.6 m max), roof-wide (roof and ceiling, 4.9 m max), 1-storey, 2-storey, 3-storey (roof, ceiling and that many storeys). The numbers 0 to 5 are also accepted. |
| opening_m | number | Opening width in metres, instead of opening_ft. Unit: m. |
| opening_ft* | number | Opening width in feet (or use opening_m). Unit: ft. |
| opening_in | number | Extra inches added to opening_ft. Unit: in. |
Checks whether removing a load-bearing wall can stay inside the Ontario Building Code Part 9 beam tables, flags when an engineer is needed, and lists the published beam size ranges from Tables 9.23.4.2.-H to -L and 9.23.4.3.-A to -J. It is not a design. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-H to -L, 9.23.4.3. and 9.23.4.3.-A to -J, Articles 9.4.1.1. and 9.23.4.1., Note A-9.23.4.2.; Building Code Act, 1992, ss. 1(1) and 8(1).
| Argument | Type | Description |
|---|---|---|
| city | string | Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead. |
| wall | string | Wall above the beam: exterior with brick veneer, or interior or exterior with siding (affects the steel tables only). |
| sr_kpa | number | Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa. |
| ss_kpa | number | Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa. |
| opening_m | number | Opening width in metres, instead of opening_ft. Unit: m. |
| opening_ft* | number | Width of the opening the beam must cross, in feet (or use opening_m). Add opening_in for extra inches. Unit: ft. |
Board feet, linear feet and piece counts for a list of dimension lumber sizes, lengths and quantities, with a waste allowance. Source: Board foot arithmetic on nominal size: thickness in x width in x length ft / 12; no code table involved.
| Argument | Type | Description |
|---|---|---|
| lines* | string | Comma separated size:length_ft:quantity, for example 2x4:8:100,2x6:12:20. Sizes: 2x4, 2x6, 2x8, 2x10, 2x12, 4x4, 4x6, 6x6. |
| waste_pct | number | Waste allowance, 0 to 50. Unit: %. |
{
"type": "object",
"required": [
"lines"
],
"properties": {
"lines": {
"type": "string",
"description": "Comma separated size:length_ft:quantity, for example 2x4:8:100,2x6:12:20. Sizes: 2x4, 2x6, 2x8, 2x10, 2x12, 4x4, 4x6, 6x6."
},
"waste_pct": {
"type": "number",
"default": 10,
"description": "Waste allowance, 0 to 50. Unit: %."
}
}
}Minimum nail length and number or spacing of nails for framing connections, from Table 9.23.3.4. of the 2024 Ontario Building Code. Filter by part of the frame and search words. Source: Ontario Building Code 2024, Division B, Table 9.23.3.4., Nailing for Framing.
| Argument | Type | Description |
|---|---|---|
| q | string | Search words in the connection description, for example stud, rafter, plate, joist. |
| group | string | Part of the frame (omit for all). |
{
"type": "object",
"required": [],
"properties": {
"q": {
"type": "string",
"description": "Search words in the connection description, for example stud, rafter, plate, joist."
},
"group": {
"enum": [
"Floor and joist framing",
"Wall framing",
"Roof framing",
"Plank decking"
],
"type": "string",
"description": "Part of the frame (omit for all)."
}
}
}Minimum footing area and thickness for a post or column from Table 9.15.3.4. (house) or from the 2.4 kPa deck load over 75 kPa soil, the minimum post size from Article 9.17.4.1., and the minimum foundation depth from Table 9.12.2.2. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.15.1.1., 9.15.3.3. to 9.15.3.8., 9.4.2.3., 9.4.4.1. (Table 9.4.4.1.), 9.12.2.2. (Table 9.12.2.2.) and 9.17.1.1. to 9.17.4.1.
| Argument | Type | Description |
|---|---|---|
| kind | string | house (interior column or post under a beam in a building) or deck (post under a deck or porch beam). |
| soil | string | Soil or rock at the footing (Table 9.4.4.1.). |
| floors | integer | House only: number of floors the column supports. |
| heated | string | Does the foundation contain a heated space (house)? Decks, porches and unheated space: no. |
| attached | string | Deck only: is the deck attached to a house or another structure? |
| drainage | string | Soil drainage to at least the depth of frost penetration. |
| height_mm | number | Deck only: distance from ground to the underside of the joists, in millimetres. Unit: mm. |
Common rafter length, roof angle, slope factor and plumb cut from the roof pitch, building span, overhang and ridge board thickness. Source: Roof geometry (Pythagorean slope factor); no code table involved.
| Argument | Type | Description |
|---|---|---|
| pitch* | number | Roof pitch, inches of rise per 12 inches of run. |
| span_ft* | number | Building span, outside of plate to outside of plate, feet. Unit: ft. |
| span_in | number | Extra inches added to span_ft. Unit: in. |
| ridge_in | number | Ridge board thickness. Unit: in. |
| overhang_in | number | Horizontal overhang past the plate. Unit: in. |
{
"type": "object",
"required": [
"pitch",
"span_ft"
],
"properties": {
"pitch": {
"type": "number",
"description": "Roof pitch, inches of rise per 12 inches of run."
},
"span_ft": {
"type": "number",
"description": "Building span, outside of plate to outside of plate, feet. Unit: ft."
},
"span_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to span_ft. Unit: in."
},
"ridge_in": {
"type": "number",
"default": 1.5,
"description": "Ridge board thickness. Unit: in."
},
"overhang_in": {
"type": "number",
"default": 12,
"description": "Horizontal overhang past the plate. Unit: in."
}
}
}Maximum horizontal span of a wood roof rafter from Table 9.23.4.2.-F of the 2024 Ontario Building Code for specified roof snow loads of 1.0 to 2.0 kPa. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-F, Maximum Spans for Roof Rafters, Specified Roof Snow Loads 1.0 to 2.0 kPa.
| Argument | Type | Description |
|---|---|---|
| size | string | Rafter size (38 mm thick). |
| grade | string | Lumber grade. |
| span_m | number | Horizontal span between the inside faces of the supports in metres, instead of span_ft. Unit: m. |
| span_ft* | number | Horizontal span between the inside faces of the supports in feet (or use span_m). Unit: ft. |
| span_in | number | Extra inches added to span_ft. Unit: in. |
| species | string | Species group. |
| snow_kpa | number | Specified roof snow load; the column at or above it is used. Unit: kPa. |
| spacing_mm | integer | Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm. |
Sheets of plywood or OSB needed to cover a floor, wall or sloped roof from its size, roof pitch, openings and waste allowance. Source: Area arithmetic (slope factor for roofs); no code table involved.
| Argument | Type | Description |
|---|---|---|
| pitch | number | Roof pitch, rise per 12 (roof only). |
| sheet | string | Sheet size, feet. |
| surface | string | Surface to cover. |
| width_ft* | number | Width in feet (wall height for a wall, plan width eave to eave for a roof). Unit: ft. |
| length_ft* | number | Length in feet (wall length for a wall). Unit: ft. |
| waste_pct | number | Waste allowance, 0 to 50. Unit: %. |
| openings_sqft | number | Openings to subtract. Unit: sq ft. |
{
"type": "object",
"required": [
"length_ft",
"width_ft"
],
"properties": {
"pitch": {
"type": "number",
"default": 6,
"description": "Roof pitch, rise per 12 (roof only)."
},
"sheet": {
"enum": [
"4x8",
"4x9",
"4x10"
],
"type": "string",
"default": "4x8",
"description": "Sheet size, feet."
},
"surface": {
"enum": [
"floor",
"wall",
"roof"
],
"type": "string",
"default": "floor",
"description": "Surface to cover."
},
"width_ft": {
"type": "number",
"description": "Width in feet (wall height for a wall, plan width eave to eave for a roof). Unit: ft."
},
"length_ft": {
"type": "number",
"description": "Length in feet (wall length for a wall). Unit: ft."
},
"waste_pct": {
"type": "number",
"default": 10,
"description": "Waste allowance, 0 to 50. Unit: %."
},
"openings_sqft": {
"type": "number",
"default": 0,
"description": "Openings to subtract. Unit: sq ft."
}
}
}Riser count and height, treads, total run and stringer length for a straight private stair, checked against Table 9.8.4.1. of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Part 9, Table 9.8.4.1. and Articles 9.8.3.3. and 9.8.4.2.
| Argument | Type | Description |
|---|---|---|
| run_mm | number | Run per tread, 255 to 355 mm. Unit: mm. |
| rise_ft | number | Total rise feet, instead of rise_mm. Unit: ft. |
| rise_in | number | Total rise extra inches, added to rise_ft. Unit: in. |
| rise_mm | number | Total rise, finished floor to finished floor, in millimetres (or use rise_ft and rise_in). Unit: mm. |
| nosing_mm | number | Tread nosing projection. Unit: mm. |
| thickness_mm | number | Tread thickness. Unit: mm. |
{
"type": "object",
"required": [],
"properties": {
"run_mm": {
"type": "number",
"default": 280,
"description": "Run per tread, 255 to 355 mm. Unit: mm."
},
"rise_ft": {
"type": "number",
"description": "Total rise feet, instead of rise_mm. Unit: ft."
},
"rise_in": {
"type": "number",
"default": 0,
"description": "Total rise extra inches, added to rise_ft. Unit: in."
},
"rise_mm": {
"type": "number",
"description": "Total rise, finished floor to finished floor, in millimetres (or use rise_ft and rise_in). Unit: mm."
},
"nosing_mm": {
"type": "number",
"default": 25,
"description": "Tread nosing projection. Unit: mm."
},
"thickness_mm": {
"type": "number",
"default": 25,
"description": "Tread thickness. Unit: mm."
}
}
}Reads the specified roof snow load for an Ontario city from SB-1 and Article 9.4.2.2., then checks whether a site-built rafter in Tables 9.23.4.2.-F and -G of the 2024 Ontario Building Code can span your roof or whether roof trusses are needed. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-F and 9.23.4.2.-G, Articles 9.4.2.1., 9.4.2.2. and 9.23.14.11.; SB-1 Table 2 (Ss and Sr).
| Argument | Type | Description |
|---|---|---|
| city | string | Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead. |
| grade | string | Lumber grade. |
| pitch | number | Roof pitch as rise per 12 of run, used only to report the sloped rafter length. |
| span_m | number | Horizontal span in metres, instead of span_ft. Unit: m. |
| sr_kpa | number | Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa. |
| ss_kpa | number | Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa. |
| span_ft* | number | Horizontal span between the inside faces of the supports, in feet (or use span_m). Unit: ft. |
Studs, plate length and plate boards for a framed wall from its length, height, stud spacing, openings, corners and intersections. Source: Timberr Framing counting rules (field studs, king and jack studs, cripples, corners, intersections, plates); headers are not sized.
| Argument | Type | Description |
|---|---|---|
| corners | integer | Number of corners (2 studs each). |
| length_m | number | Wall length in metres, instead of length_ft. Unit: m. |
| openings | string | Comma separated type:rough-opening-width-in-inches, for example door:36,window:48. |
| height_ft | number | Wall height, feet. Unit: ft. |
| length_ft* | number | Wall length, feet (or use length_m). Add length_in for extra inches. Unit: ft. |
| length_in | number | Extra inches added to length_ft. Unit: in. |
| waste_pct | number | Waste allowance, 0 to 50. Unit: %. |
| spacing_in | integer | Stud spacing on centre. Unit: in. |
We read every tool's name, description and inputs the way the model will, looking for instructions hidden from you. A clean result means no warning signs, not a guarantee. Scanned Nov 16, 2026.
{
"type": "object",
"required": [],
"properties": {
"wall_use": {
"enum": [
"party-wall",
"suites",
"secondary-suite",
"garage-garage",
"garage-dwelling"
],
"type": "string",
"default": "party-wall",
"description": "What the wall separates: party-wall (dwelling units on either side of a property line, such as townhouses or semi-detached houses), suites (units in one building with no property line, such as a duplex, triplex or stacked units), secondary-suite (a house with a secondary suite), garage-garage (two attached garages across a property line), garage-dwelling (a garage and the dwelling it serves)."
},
"sprinklered": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Is the house with a secondary suite sprinklered? Used for the secondary-suite case only."
},
"two_storey_unit": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "yes",
"description": "Does a dwelling unit have 2 or more storeys, counting the basement?"
},
"unit_above_unit": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Is any dwelling unit above another dwelling unit (stacked units)?"
},
"garage_serves_dwelling": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "yes",
"description": "Does the garage serve only the dwelling it is attached to? Used for garage-dwelling only."
}
}
}{
"type": "object",
"required": [
"span_ft"
],
"properties": {
"size": {
"enum": [
"2x4",
"2x6",
"2x8",
"2x10",
"2x12"
],
"type": "string",
"default": "2x10",
"description": "Joist or rafter size (38 mm thick)."
},
"grade": {
"enum": [
"SS",
"No1",
"No3"
],
"type": "string",
"default": "No1",
"description": "Lumber grade."
},
"span_m": {
"type": "number",
"description": "Clear span between the inside faces of the supports in metres, instead of span_ft. Unit: m."
},
"span_ft": {
"type": "number",
"description": "Clear span between the inside faces of the supports in feet (or use span_m). Unit: ft."
},
"span_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to span_ft. Unit: in."
},
"species": {
"enum": [
"SPF",
"DFL",
"Hem-Fir",
"Northern"
],
"type": "string",
"default": "SPF",
"description": "Species group."
},
"support": {
"enum": [
"strapping",
"bridging",
"both"
],
"type": "string",
"default": "strapping",
"description": "Bridging and strapping."
},
"spacing_mm": {
"enum": [
300,
400,
600
],
"type": "integer",
"default": 400,
"description": "Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm."
}
}
}| floor_joists_full_width | string | Floor joists span the full building width without support (table note 3 reduction for 1 to 3 storeys). |
{
"type": "object",
"required": [
"opening_ft"
],
"properties": {
"wall": {
"enum": [
"exterior",
"interior"
],
"type": "string",
"default": "exterior",
"description": "Exterior or interior wall (attic is always interior)."
},
"species": {
"enum": [
"SPF",
"DFL",
"Hem-Fir"
],
"type": "string",
"default": "SPF",
"description": "Lumber species group (No. 1 or No. 2 grade)."
},
"snow_kpa": {
"enum": [
1,
1.5,
2,
2.5,
3
],
"type": "number",
"default": 1.5,
"description": "Specified roof snow load for exterior walls; the column at or above it is used. Unit: kPa."
},
"supports": {
"enum": [
"attic",
"roof",
"roof-wide",
"1-storey",
"2-storey",
"3-storey"
],
"type": "string",
"default": "1-storey",
"description": "What the lintel supports: attic (limited attic storage and ceiling), roof (roof and ceiling, tributary width 0.6 m max), roof-wide (roof and ceiling, 4.9 m max), 1-storey, 2-storey, 3-storey (roof, ceiling and that many storeys). The numbers 0 to 5 are also accepted."
},
"opening_m": {
"type": "number",
"description": "Opening width in metres, instead of opening_ft. Unit: m."
},
"opening_ft": {
"type": "number",
"description": "Opening width in feet (or use opening_m). Unit: ft."
},
"opening_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to opening_ft. Unit: in."
},
"floor_joists_full_width": {
"enum": [
"no",
"yes"
],
"type": "string",
"default": "no",
"description": "Floor joists span the full building width without support (table note 3 reduction for 1 to 3 storeys)."
}
}
}| opening_in | number | Extra inches added to opening_ft. Unit: in. |
| roof_above | string | Does roof framing (rafters, joists or trusses) bear on this wall? |
| point_loads | string | Does a post, a girder truss, a stair or another beam land on the beam as a point load? |
| floors_above | integer | Number of floors bearing on the wall, not counting the roof. |
| trusses_bear | string | Do roof trusses bear on the wall being removed? |
| roof_supported_ft | number | Supported roof length: half the sum of rafter, joist or truss spans on both sides, in feet. Unit: ft. |
| floor_supported_ft | number | Supported floor joist length: half the sum of the joist spans on both sides of the beam, in feet. Unit: ft. |
{
"type": "object",
"required": [
"opening_ft"
],
"properties": {
"city": {
"enum": [
"toronto",
"etobicoke",
"north-york",
"scarborough",
"mississauga",
"brampton",
"vaughan",
"markham",
"richmond-hill",
"aurora",
"newmarket",
"uxbridge",
"bradford",
"barrie",
"oakville",
"burlington",
"milton",
"caledon",
"ajax",
"whitby",
"oshawa",
"hamilton-below-escarpment",
"hamilton-above-escarpment",
"cambridge",
"guelph",
"kitchener",
"waterloo",
"bracebridge",
"gravenhurst",
"huntsville",
"collingwood",
"parry-sound"
],
"type": "string",
"description": "Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead."
},
"wall": {
"enum": [
"siding",
"brick"
],
"type": "string",
"default": "siding",
"description": "Wall above the beam: exterior with brick veneer, or interior or exterior with siding (affects the steel tables only)."
},
"sr_kpa": {
"type": "number",
"default": 0.4,
"description": "Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"ss_kpa": {
"type": "number",
"description": "Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"opening_m": {
"type": "number",
"description": "Opening width in metres, instead of opening_ft. Unit: m."
},
"opening_ft": {
"type": "number",
"description": "Width of the opening the beam must cross, in feet (or use opening_m). Add opening_in for extra inches. Unit: ft."
},
"opening_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to opening_ft. Unit: in."
},
"roof_above": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "yes",
"description": "Does roof framing (rafters, joists or trusses) bear on this wall?"
},
"point_loads": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Does a post, a girder truss, a stair or another beam land on the beam as a point load?"
},
"floors_above": {
"enum": [
0,
1,
2,
3
],
"type": "integer",
"default": 1,
"description": "Number of floors bearing on the wall, not counting the roof."
},
"trusses_bear": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Do roof trusses bear on the wall being removed?"
},
"roof_supported_ft": {
"type": "number",
"default": 12,
"description": "Supported roof length: half the sum of rafter, joist or truss spans on both sides, in feet. Unit: ft."
},
"floor_supported_ft": {
"type": "number",
"default": 10,
"description": "Supported floor joist length: half the sum of the joist spans on both sides of the beam, in feet. Unit: ft."
}
}
}| roof_over | string | Deck only: does the deck support a roof? |
| beam_span_ft | number | Deck only: supported beam length, half the sum of the beam spans on both sides of the post, in feet. At most 10 ft. Unit: ft. |
| deck_area_m2 | number | Deck only: deck area in square metres, for the floating deck check in Sentence 9.12.2.2.(7). Unit: m2. |
| joist_span_ft | number | Supported joist length, in feet: half the sum of the joist spans on both sides of the beam. House: at most 16 ft (4.9 m). Unit: ft. |
| high_water_table | string | Is the water table less than the footing width below the bearing surface? It doubles the footing area on gravel, sand or silt (Article 9.15.3.4.(3)). |
| column_spacing_ft | number | House only: spacing of the columns along the beam, in feet. The table is for 3 m (9.8 ft) and the area is adjusted in proportion (Article 9.15.3.7.). Unit: ft. |
{
"type": "object",
"required": [],
"properties": {
"kind": {
"enum": [
"house",
"deck"
],
"type": "string",
"default": "house",
"description": "house (interior column or post under a beam in a building) or deck (post under a deck or porch beam)."
},
"soil": {
"enum": [
"rock",
"till",
"dense-sand-gravel",
"dense-silt",
"stiff-clay",
"firm-clay",
"loose-sand-gravel",
"soft-clay",
"peat",
"fill",
"sensitive-clay"
],
"type": "string",
"default": "firm-clay",
"description": "Soil or rock at the footing (Table 9.4.4.1.)."
},
"floors": {
"enum": [
1,
2,
3
],
"type": "integer",
"default": 1,
"description": "House only: number of floors the column supports."
},
"heated": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "yes",
"description": "Does the foundation contain a heated space (house)? Decks, porches and unheated space: no."
},
"attached": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "yes",
"description": "Deck only: is the deck attached to a house or another structure?"
},
"drainage": {
"enum": [
"good",
"poor"
],
"type": "string",
"default": "good",
"description": "Soil drainage to at least the depth of frost penetration."
},
"height_mm": {
"type": "number",
"default": 600,
"description": "Deck only: distance from ground to the underside of the joists, in millimetres. Unit: mm."
},
"roof_over": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Deck only: does the deck support a roof?"
},
"beam_span_ft": {
"type": "number",
"default": 8,
"description": "Deck only: supported beam length, half the sum of the beam spans on both sides of the post, in feet. At most 10 ft. Unit: ft."
},
"deck_area_m2": {
"type": "number",
"default": 20,
"description": "Deck only: deck area in square metres, for the floating deck check in Sentence 9.12.2.2.(7). Unit: m2."
},
"joist_span_ft": {
"type": "number",
"default": 10,
"description": "Supported joist length, in feet: half the sum of the joist spans on both sides of the beam. House: at most 16 ft (4.9 m). Unit: ft."
},
"high_water_table": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Is the water table less than the footing width below the bearing surface? It doubles the footing area on gravel, sand or silt (Article 9.15.3.4.(3))."
},
"column_spacing_ft": {
"type": "number",
"default": 10,
"description": "House only: spacing of the columns along the beam, in feet. The table is for 3 m (9.8 ft) and the area is adjusted in proportion (Article 9.15.3.7.). Unit: ft."
}
}
}{
"type": "object",
"required": [
"span_ft"
],
"properties": {
"size": {
"enum": [
"2x4",
"2x6",
"2x8",
"2x10",
"2x12"
],
"type": "string",
"default": "2x10",
"description": "Rafter size (38 mm thick)."
},
"grade": {
"enum": [
"SS",
"No1",
"No3"
],
"type": "string",
"default": "No1",
"description": "Lumber grade."
},
"span_m": {
"type": "number",
"description": "Horizontal span between the inside faces of the supports in metres, instead of span_ft. Unit: m."
},
"span_ft": {
"type": "number",
"description": "Horizontal span between the inside faces of the supports in feet (or use span_m). Unit: ft."
},
"span_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to span_ft. Unit: in."
},
"species": {
"enum": [
"SPF",
"DFL",
"Hem-Fir",
"Northern"
],
"type": "string",
"default": "SPF",
"description": "Species group."
},
"snow_kpa": {
"enum": [
1,
1.5,
2
],
"type": "number",
"default": 1.5,
"description": "Specified roof snow load; the column at or above it is used. Unit: kPa."
},
"spacing_mm": {
"enum": [
300,
400,
600
],
"type": "integer",
"default": 400,
"description": "Spacing on centre (12, 16 and 24 in are also accepted). Unit: mm."
}
}
}| span_in | number | Extra inches added to span_ft. Unit: in. |
| species | string | Species group. |
| spacing_mm | integer | Rafter spacing on centre (12, 16 and 24 in are also accepted). Unit: mm. |
| narrow_roof | string | Is the entire roof width 4.3 m or less? (Article 9.4.2.2.: basic roof factor Cb 0.45 instead of 0.55.) |
{
"type": "object",
"required": [
"span_ft"
],
"properties": {
"city": {
"enum": [
"toronto",
"etobicoke",
"north-york",
"scarborough",
"mississauga",
"brampton",
"vaughan",
"markham",
"richmond-hill",
"aurora",
"newmarket",
"uxbridge",
"bradford",
"barrie",
"oakville",
"burlington",
"milton",
"caledon",
"ajax",
"whitby",
"oshawa",
"hamilton-below-escarpment",
"hamilton-above-escarpment",
"cambridge",
"guelph",
"kitchener",
"waterloo",
"bracebridge",
"gravenhurst",
"huntsville",
"collingwood",
"parry-sound"
],
"type": "string",
"description": "Ontario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead."
},
"grade": {
"enum": [
"SS",
"No1",
"No3"
],
"type": "string",
"default": "No1",
"description": "Lumber grade."
},
"pitch": {
"type": "number",
"default": 6,
"description": "Roof pitch as rise per 12 of run, used only to report the sloped rafter length."
},
"span_m": {
"type": "number",
"description": "Horizontal span in metres, instead of span_ft. Unit: m."
},
"sr_kpa": {
"type": "number",
"default": 0.4,
"description": "Rain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"ss_kpa": {
"type": "number",
"description": "Ground snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa."
},
"span_ft": {
"type": "number",
"description": "Horizontal span between the inside faces of the supports, in feet (or use span_m). Unit: ft."
},
"span_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to span_ft. Unit: in."
},
"species": {
"enum": [
"SPF",
"DFL",
"Hem-Fir",
"Northern"
],
"type": "string",
"default": "SPF",
"description": "Species group."
},
"spacing_mm": {
"enum": [
300,
400,
600
],
"type": "integer",
"default": 400,
"description": "Rafter spacing on centre (12, 16 and 24 in are also accepted). Unit: mm."
},
"narrow_roof": {
"enum": [
"yes",
"no"
],
"type": "string",
"default": "no",
"description": "Is the entire roof width 4.3 m or less? (Article 9.4.2.2.: basic roof factor Cb 0.45 instead of 0.55.)"
}
}
}| top_plates |
| integer |
| Top plate courses. |
| intersections | integer | Places another wall meets this wall (2 studs each). |
{
"type": "object",
"required": [
"length_ft"
],
"properties": {
"corners": {
"type": "integer",
"default": 2,
"description": "Number of corners (2 studs each)."
},
"length_m": {
"type": "number",
"description": "Wall length in metres, instead of length_ft. Unit: m."
},
"openings": {
"type": "string",
"description": "Comma separated type:rough-opening-width-in-inches, for example door:36,window:48."
},
"height_ft": {
"type": "number",
"default": 8,
"description": "Wall height, feet. Unit: ft."
},
"length_ft": {
"type": "number",
"description": "Wall length, feet (or use length_m). Add length_in for extra inches. Unit: ft."
},
"length_in": {
"type": "number",
"default": 0,
"description": "Extra inches added to length_ft. Unit: in."
},
"waste_pct": {
"type": "number",
"default": 10,
"description": "Waste allowance, 0 to 50. Unit: %."
},
"spacing_in": {
"enum": [
12,
16,
24
],
"type": "integer",
"default": 16,
"description": "Stud spacing on centre. Unit: in."
},
"top_plates": {
"enum": [
1,
2
],
"type": "integer",
"default": 2,
"description": "Top plate courses."
},
"intersections": {
"type": "integer",
"default": 0,
"description": "Places another wall meets this wall (2 studs each)."
}
}
}