PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
Maintain this server? Claim it
Call this server's tools from your browser. Nothing to install.
Requests go through mcptry because browsers can't call most MCP servers directly. Header values are sent to the server for that request only and are never stored or logged.
Tool list from our last check. Connect live to refresh it.
Convert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
This tool isn't marked read-only, so it may change something on the server or in an account you connected.
Convert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
| Argument | Type | Description |
|---|---|---|
| value* | number | |
| to_unit* | string | |
| from_unit* | string |
{
"type": "object",
"title": "convert_unitsArguments",
"required": [
"value",
"from_unit",
"to_unit"
],
"properties": {
"value": {
"type": "number",
"title": "Value"
},
"to_unit": {
"type": "string",
"title": "To Unit"
},
"from_unit": {
"type": "string",
"title": "From Unit"
}
}
}About CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
No arguments.
{
"type": "object",
"title": "coolbooked_infoArguments",
"properties": {}
}Conversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems.
| Argument | Type | Description |
|---|---|---|
| metering | string | |
| ambient_f* | number | |
| head_psig* | number | |
| refrigerant* | string | |
| suction_psig* | number | |
| liquid_line_f* | number | |
| suction_line_f* | number |
{
"type": "object",
"title": "diagnoseArguments",
"required": [
"refrigerant",
"suction_psig",
"suction_line_f",
"head_psig",
"liquid_line_f",
"ambient_f"
],
"properties": {
"metering": {
"type": "string",
"title": "Metering",
"default": "txv"
},
"ambient_f": {
"type": "number",
"title": "Ambient F"
},
"head_psig": {
"type": "number",
"title": "Head Psig"
},
"refrigerant": {
"type": "string",
"title": "Refrigerant"
},
"suction_psig": {
"type": "number",
"title": "Suction Psig"
},
"liquid_line_f": {
"type": "number",
"title": "Liquid Line F"
},
"suction_line_f": {
"type": "number",
"title": "Suction Line F"
}
}
}Saturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match.
| Argument | Type | Description |
|---|---|---|
| temp_f* | number | |
| refrigerant* | string |
{
"type": "object",
"title": "pt_lookupArguments",
"required": [
"refrigerant",
"temp_f"
],
"properties": {
"temp_f": {
"type": "number",
"title": "Temp F"
},
"refrigerant": {
"type": "string",
"title": "Refrigerant"
}
}
}Saturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants.
| Argument | Type | Description |
|---|---|---|
| refrigerant* | string | |
| pressure_psig* | number |
{
"type": "object",
"title": "pt_reverseArguments",
"required": [
"refrigerant",
"pressure_psig"
],
"properties": {
"refrigerant": {
"type": "string",
"title": "Refrigerant"
},
"pressure_psig": {
"type": "number",
"title": "Pressure Psig"
}
}
}Reference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
| Argument | Type | Description |
|---|---|---|
| refrigerant* | string |
{
"type": "object",
"title": "refrigerant_infoArguments",
"required": [
"refrigerant"
],
"properties": {
"refrigerant": {
"type": "string",
"title": "Refrigerant"
}
}
}Subcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
| Argument | Type | Description |
|---|---|---|
| head_psig* | number | |
| refrigerant* | string | |
| liquid_line_f* | number |
{
"type": "object",
"title": "subcoolingArguments",
"required": [
"refrigerant",
"head_psig",
"liquid_line_f"
],
"properties": {
"head_psig": {
"type": "number",
"title": "Head Psig"
},
"refrigerant": {
"type": "string",
"title": "Refrigerant"
},
"liquid_line_f": {
"type": "number",
"title": "Liquid Line F"
}
}
}Superheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
| Argument | Type | Description |
|---|---|---|
| refrigerant* | string | |
| suction_psig* | number | |
| suction_line_f* | number |
{
"type": "object",
"title": "superheatArguments",
"required": [
"refrigerant",
"suction_psig",
"suction_line_f"
],
"properties": {
"refrigerant": {
"type": "string",
"title": "Refrigerant"
},
"suction_psig": {
"type": "number",
"title": "Suction Psig"
},
"suction_line_f": {
"type": "number",
"title": "Suction Line F"
}
}
}