27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).
Maintain this server? Claim it
Call this server's tools from your browser. Nothing to install.
Requests go through mcptry because browsers can't call most MCP servers directly. Header values are sent to the server for that request only and are never stored or logged.
Tool list from our last check. Connect live to refresh it.
Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures.
e.g. germany, france, netherlands, ireland, uk
e.g. office, residential, retail, school, hospital
gas_boiler, heat_pump, district_heating, electric, oil_boiler, biomass
This tool isn't marked read-only, so it may change something on the server or in an account you connected.
Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures.
| Argument | Type | Description |
|---|---|---|
| country* | string | e.g. germany, france, netherlands, ireland, uk |
| year_built* | integer | |
| current_epc* | string | |
| has_solar_pv* | boolean | |
| building_type* | string | e.g. office, residential, retail, school, hospital |
| floor_area_m2* | number | |
| heating_system* | string | gas_boiler, heat_pump, district_heating, electric, oil_boiler, biomass |
{
"type": "object",
"required": [
"building_type",
"year_built",
"current_epc",
"heating_system",
"has_solar_pv",
"floor_area_m2",
"country"
],
"properties": {
"country": {
"type": "string",
"description": "e.g. germany, france, netherlands, ireland, uk"
},
"year_built": {
"type": "integer"
},
"current_epc": {
"enum": [
"A",
"B",
"C",
"D",
"E",
"F",
"G"
],
"type": "string"
},
"has_solar_pv": {
"type": "boolean"
},
"building_type": {
"type": "string",
"description": "e.g. office, residential, retail, school, hospital"
},
"floor_area_m2": {
"type": "number"
},
"heating_system": {
"type": "string",
"description": "gas_boiler, heat_pump, district_heating, electric, oil_boiler, biomass"
}
}
}Building carbon footprint (Scope 1/2/3) with CRREM stranding check and embodied carbon. Returns per-scope tCO2e, intensity, CRREM compliance, net-zero gap and priority actions.
| Argument | Type | Description |
|---|---|---|
| location* | string | |
| occupancy | number | |
| year_built* | integer | |
| refrigerant | string | |
| gas_kwh_year | number | |
| building_type* | string | |
| elec_kwh_year | number | |
| floor_area_m2* | number | |
| heat_kwh_year | number | |
| renewable_pct | number |
Building Readiness assessment for change-of-use / conversion. Returns a 0-100 readiness score, project complexity, four domain scores (structural, MEP, compliance, digital/BIM) with RAG, and recommendations.
| Argument | Type | Description |
|---|---|---|
| bim* | string | |
| floors* | string | |
| location* | string | |
| condition* | string | |
| structure* | string | |
| year_built* | string | |
| current_use* | string | |
| proposed_use* | string |
{
"type": "object",
"required": [
"current_use",
"proposed_use",
"year_built",
"structure",
"floors",
"condition",
"location",
"bim"
],
"properties": {
"bim": {
"enum": [
"yes",
"partial",
"no"
],
"type": "string"
},
"floors": {
"enum": [
"1-3",
"4-6",
"7-10",
"10+"
],
"type": "string"
},
"location": {
"enum": [
"uk",
"western-eu",
"eastern-eu",
"uae"
],
"type": "string"
},
"condition": {
"enum": [
"good",
"fair",
"poor",
"unknown"
],
"type": "string"
},
"structure": {
"enum": [
"concrete",
"steel",
"masonry",
"timber",
"unknown"
],
"type": "string"
},
"year_built": {
"enum": [
"pre1945",
"1945-1970",
"1970-1990",
"1990-2010",
"post2010"
],
"type": "string"
},
"current_use": {
"enum": [
"office",
"industrial",
"retail",
"residential"
],
"type": "string"
},
"proposed_use": {
"enum": [
"office",
"residential",
"healthcare",
"industrial",
"retail"
],
"type": "string"
}
}
}Calculate operational + embodied carbon and net-zero gap (CIBSE TM65 / RICS WLCA). Returns carbon intensity, benchmark, and prioritised reduction measures with payback.
| Argument | Type | Description |
|---|---|---|
| country* | string | ISO-2: gb, de, fr, nl, es, pl, ro, it, ae, us |
| building_type* | string | office, residential, retail, industrial, hospital, warehouse, hotel |
| floor_area_m2* | number | |
| energy_kwh_year | number | Measured annual energy; 0 to use benchmark |
| construction_year | integer |
{
"type": "object",
"required": [
"floor_area_m2",
"building_type",
"country"
],
"properties": {
"country": {
"type": "string",
"description": "ISO-2: gb, de, fr, nl, es, pl, ro, it, ae, us"
},
"building_type": {
"type": "string",
"description": "office, residential, retail, industrial, hospital, warehouse, hotel"
},
"floor_area_m2": {
"type": "number"
},
"energy_kwh_year": {
"type": "number",
"description": "Measured annual energy; 0 to use benchmark"
},
"construction_year": {
"type": "integer"
}
}
}Calculate Power Usage Effectiveness (PUE) for a data centre or server room. Returns PUE score, efficiency rating, annual cost estimate, and engineering recommendations.
| Argument | Type | Description |
|---|---|---|
| cooling_kw* | number | Total cooling system power in kW. Example: 200 |
| it_load_kw* | number | IT equipment power draw in kW. Example: 500 |
| lighting_kw* | number | Lighting power in kW. Example: 1.5 |
| ups_losses_kw* | number | UPS and power distribution losses in kW. Example: 25 |
{
"type": "object",
"required": [
"it_load_kw",
"cooling_kw",
"ups_losses_kw",
"lighting_kw"
],
"properties": {
"cooling_kw": {
"type": "number",
"description": "Total cooling system power in kW. Example: 200"
},
"it_load_kw": {
"type": "number",
"description": "IT equipment power draw in kW. Example: 500"
},
"lighting_kw": {
"type": "number",
"description": "Lighting power in kW. Example: 1.5"
},
"ups_losses_kw": {
"type": "number",
"description": "UPS and power distribution losses in kW. Example: 25"
}
}
}Assess UAE grid connection feasibility (DEWA/ADDC/SEWA/FEWA). Returns feasibility score, connection timeline, recommended voltage, substation requirement, and next steps.
| Argument | Type | Description |
|---|---|---|
| intended_use* | string | |
| site_location* | string | |
| voltage_level* | string | |
| has_existing_supply* | boolean | |
| power_requirement_mw* | number | |
| target_completion_year* | integer |
{
"type": "object",
"required": [
"site_location",
"power_requirement_mw",
"voltage_level",
"intended_use",
"has_existing_supply",
"target_completion_year"
],
"properties": {
"intended_use": {
"enum": [
"data_centre",
"commercial",
"industrial",
"mixed"
],
"type": "string"
},
"site_location": {
"enum": [
"dubai",
"abu_dhabi",
"sharjah",
"ajman",
"other"
],
"type": "string"
},
"voltage_level": {
"enum": [
"LV",
"MV",
"HV"
],
"type": "string"
},
"has_existing_supply": {
"type": "boolean"
},
"power_requirement_mw": {
"type": "number"
},
"target_completion_year": {
"type": "integer"
}
}
}Assess NIS2 Directive (EU 2022/2555) compliance readiness. Returns compliance score (0-18), maturity level, estimated fine exposure, and prioritised remediation actions.
| Argument | Type | Description |
|---|---|---|
| sector* | string | e.g. energy, transport, healthcare, banking |
| has_ciso* | boolean | |
| has_ir_plan* | boolean | |
| has_ot_policy* | boolean | |
| has_24h_reporting* | boolean | |
| has_ot_monitoring* | boolean | |
| organisation_size* | string | |
| has_asset_inventory* | boolean | |
| has_board_reporting* | boolean | |
Check UAE BIM mandate applicability (Dubai Circular 196, Abu Dhabi DMT, Sharjah). Returns mandate status, compliance score, required LOD, and submission checklist.
| Argument | Type | Description |
|---|---|---|
| emirate* | string | |
| has_bep* | boolean | |
| ifc_export* | boolean | |
| bim_software* | string | e.g. Revit 2024 |
| building_type* | string | |
| has_bim_model* | boolean | |
| building_floors* | integer | |
| building_area_m2* | number |
{
"type": "object",
"required": [
"building_area_m2",
"building_floors",
"emirate",
"building_type",
"has_bim_model",
"bim_software",
"ifc_export",
"has_bep"
],
"properties": {
"emirate": {
"enum": [
"dubai",
"abu_dhabi",
"sharjah",
"other"
],
"type": "string"
},
"has_bep": {
"type": "boolean"
},
"ifc_export": {
"type": "boolean"
},
"bim_software": {
"type": "string",
"description": "e.g. Revit 2024"
},
"building_type": {
"enum": [
"residential",
"commercial",
"healthcare",
"government",
"mixed"
],
"type": "string"
},
"has_bim_model": {
"type": "boolean"
},
"building_floors": {
"type": "integer"
},
"building_area_m2": {
"type": "number"
}
}
}Assess UAE cybersecurity regulatory compliance (NESA IAS, Dubai ISR, CBUAE, TDRA). Returns applicable framework, compliance score, critical gaps, and mandatory controls.
| Argument | Type | Description |
|---|---|---|
| emirate* | string | dubai, abu_dhabi, sharjah, federal, other |
| has_isms* | boolean | |
| is_cloud_hosted* | boolean | |
| organisation_type* | string | |
| has_incident_response* | boolean | |
| has_third_party_audit* | boolean | |
| has_data_classification* | boolean | |
| has_vulnerability_assessment* | boolean |
{
"type": "object",
"required": [
"organisation_type",
"emirate",
"has_isms",
"has_incident_response",
"has_vulnerability_assessment",
"has_third_party_audit",
"has_data_classification",
"is_cloud_hosted"
],
"properties": {
"emirate": {
"type": "string",
"description": "dubai, abu_dhabi, sharjah, federal, other"
},
"has_isms": {
"type": "boolean"
},
"is_cloud_hosted": {
"type": "boolean"
},
"organisation_type": {
"enum": [
"government",
"critical_infrastructure",
"financial",
"telecom",
"other"
],
"type": "string"
},
"has_incident_response": {
"type": "boolean"
},
"has_third_party_audit": {
"type": "boolean"
},
"has_data_classification": {
"type": "boolean"
},
"has_vulnerability_assessment": {
"type": "boolean"
}
}
}NIS2 / EPBD contractor vetting score from a 12-question checklist across financial, technical, cyber (NIS2) and energy (EPBD) categories. Flags blocking (critical) failures and returns recommended additional checks. Not a formal due-diligence report.
| Argument | Type | Description |
|---|---|---|
| answers* | object | Map of question_id -> yes|no|unknown. IDs: registered, insurance, no_prosecutions, certifications, references, cvs, cyber_policy, incident_reporting, access_control, assessor_cert, energy_qual, reno_experience |
| purpose | string | Vetting purpose |
{
"type": "object",
"required": [
"answers"
],
"properties": {
"answers": {
"type": "object",
"description": "Map of question_id -> yes|no|unknown. IDs: registered, insurance, no_prosecutions, certifications, references, cvs, cyber_policy, incident_reporting, access_control, assessor_cert, energy_qual, reno_experience"
},
"purpose": {
"enum": [
"nis2",
"epbd",
"general",
"critical"
],
"type": "string",
"description": "Vetting purpose"
}
}
}DGNB certification pre-score and BIM (ISO 19650) maturity self-assessment from a 20-question checklist. Returns pre-score, achievable certification level, BIM level, domain breakdown and prioritised gaps. Not a formal DGNB audit.
| Argument | Type | Description |
|---|---|---|
| answers* | object | Map of question_id -> yes|partial|no. IDs: lca, materials, water, biodiversity, lcc, flexibility, value_stability, cert_budget, comfort, accessibility, wellbeing, satisfaction, bep, cde, competency, clash, integrated_team, commissioning, documentation, poe |
| cert_target | string | Target DGNB level |
{
"type": "object",
"required": [
"answers"
],
"properties": {
"answers": {
"type": "object",
"description": "Map of question_id -> yes|partial|no. IDs: lca, materials, water, biodiversity, lcc, flexibility, value_stability, cert_budget, comfort, accessibility, wellbeing, satisfaction, bep, cde, competency, clash, integrated_team, commissioning, documentation, poe"
},
"cert_target": {
"enum": [
"bronze",
"silver",
"gold",
"platinum"
],
"type": "string",
"description": "Target DGNB level"
}
}
}EPBD-style staged digital renovation passport: 3-phase roadmap (quick wins, system upgrades, deep renovation) with cost ranges, energy savings and EPC trajectory from current EPC, floor area and heating type. Indicative.
| Argument | Type | Description |
|---|---|---|
| era | string | Construction era (label only) |
| address | string | Building address (label only) |
| country | string | Country code (e.g. UK, DE) |
| heating* | string | Primary heating system |
| current_epc* | string | Current EPC band A-G |
| building_type | string | Building type (label only) |
| floor_area_m2* | number | Gross floor area (m2) |
{
"type": "object",
"required": [
"floor_area_m2",
"current_epc",
"heating"
],
"properties": {
"era": {
"type": "string",
"description": "Construction era (label only)"
},
"address": {
"type": "string",
"description": "Building address (label only)"
},
"country": {
"type": "string",
"description": "Country code (e.g. UK, DE)"
},
"heating": {
"enum": [
"gas",
"oil",
"hp",
"district",
"electric",
"biomass"
],
"type": "string",
"description": "Primary heating system"
},
"current_epc": {
"enum": [
"A",
"B",
"C",
"D",
"E",
"F",
"G"
],
"type": "string",
"description": "Current EPC band A-G"
},
"building_type": {
"type": "string",
"description": "Building type (label only)"
},
"floor_area_m2": {
"type": "number",
"description": "Gross floor area (m2)"
}
}
}EU Energy Efficiency Directive data-centre reporting pack (Dir (EU) 2023/1791 Art.12 + Del. Reg (EU) 2024/1364). Determines reporting scope (IT power >= 500 kW) and computes the mandated KPIs PUE, WUE, ERF and REF. Note: the regulation mandates reporting, not target values.
| Argument | Type | Description |
|---|---|---|
| it_power_kw* | number | Installed IT power demand (kW) |
| it_energy_kwh* | number | EIT: IT energy (kWh/yr) |
| water_input_m3 | number | WIN: total water input (m3/yr), for WUE |
| reused_heat_kwh | number | EREUSE waste heat reused, for ERF |
| total_energy_kwh* | number | EDC: total data-centre energy (kWh/yr) |
| renewable_energy_kwh | number | ERES-TOT renewable energy consumed, for REF |
{
"type": "object",
"required": [
"it_power_kw",
"total_energy_kwh",
"it_energy_kwh"
],
"properties": {
"it_power_kw": {
"type": "number",
"description": "Installed IT power demand (kW)"
},
"it_energy_kwh": {
"type": "number",
"description": "EIT: IT energy (kWh/yr)"
},
"water_input_m3": {
"type": "number",
"description": "WIN: total water input (m3/yr), for WUE"
},
"reused_heat_kwh": {
"type": "number",
"description": "EREUSE waste heat reused, for ERF"
},
"total_energy_kwh": {
"type": "number",
"description": "EDC: total data-centre energy (kWh/yr)"
},
"renewable_energy_kwh": {
"type": "number",
"description": "ERES-TOT renewable energy consumed, for REF"
}
}
}Estimate cooling load using CIBSE Guide B2 / ASHRAE methodology. Returns required capacity, installed capacity with redundancy, system recommendation, and annual energy.
| Argument | Type | Description |
|---|---|---|
| it_load_kw* | number | Required for data_centre/server_room. Set 0 for others. |
| redundancy* | string | |
| space_type* | string | |
| climate_zone* | string | |
| floor_area_m2* | number | |
| occupancy_persons* | integer |
{
"type": "object",
"required": [
"space_type",
"floor_area_m2",
"it_load_kw",
"occupancy_persons",
"climate_zone",
"redundancy"
],
"properties": {
"it_load_kw": {
"type": "number",
"description": "Required for data_centre/server_room. Set 0 for others."
},
"redundancy": {
"enum": [
"N",
"N+1",
"2N"
],
"type": "string"
},
"space_type": {
"enum": [
"office",
"data_centre",
"server_room",
"retail",
"industrial"
],
"type": "string"
},
"climate_zone": {
"enum": [
"northern_eu",
"central_eu",
"southern_eu",
"uk",
"uae_gcc"
],
"type": "string"
},
"floor_area_m2": {
"type": "number"
},
"occupancy_persons": {
"type": "integer"
}
}
}Parametric construction cost benchmark across UK/EU/GCC by country, project type, specification, procurement, programme and BIM. Returns per-m2 and total cost ranges plus a cost breakdown. Indicative parametric estimate, validate against current cost indices.
| Argument | Type | Description |
|---|---|---|
| bim | string | |
| country* | string | Country |
| programme | string | |
| procurement | string | |
| project_type* | string | Project type |
| floor_area_m2* | number | Gross floor area (m2), min 100 |
| specification | string |
{
"type": "object",
"required": [
"floor_area_m2",
"country",
"project_type"
],
"properties": {
"bim": {
"enum": [
"yes",
"no"
],
"type": "string"
},
"country": {
"enum": [
"UK",
"DE",
"FR",
"NL",
"ES",
"PL",
"RO",
"BE",
"AT",
"UAE",
"SA"
],
"type": "string",
"description": "Country"
},
"programme": {
"enum": [
"accelerated",
"standard",
"extended"
],
"type": "string"
},
"procurement": {
"enum": [
"traditional",
"db",
"epc",
"ppp"
],
"type": "string"
},
"project_type": {
"enum": [
"office_new",
"resi_new",
"data_centre",
"industrial",
"healthcare",
"retail",
"reno_light",
"reno_deep",
"infrastructure"
],
"type": "string",
"description": "Project type"
},
"floor_area_m2": {
"type": "number",
"description": "Gross floor area (m2), min 100"
},
"specification": {
"enum": [
"basic",
"standard",
"premium",
"ultra"
],
"type": "string"
}
}
}Preliminary Eurocode beam design (steel EC3 / composite / reinforced concrete EC2). Selects a section, computes ULS bending & shear utilisation, SLS deflection, and fire protection. Indicative, not a stamped design.
| Argument | Type | Description |
|---|---|---|
| grade | string | Steel: s275/s355. Concrete: c2530/c3037/c3545 |
| config* | string | ss=simply supported, cant=cantilever, cont=continuous 2-span |
| span_m* | number | Span length (m) |
| exposure | string | Concrete exposure class (cover) |
| material* | string | Beam material |
| udl_kn_m* | number | Characteristic uniformly distributed load (kN/m) |
| fire_rating | string | Required fire rating |
| load_position | number | Point-load position as fraction of span 0-1 (default 0.5) |
| point_load_kn | number | Characteristic point load (kN), optional |
Eurocode axial column buckling check (steel EC3 6.3.1 flexural buckling / RC EC2 5.8 simplified). Returns Ncr, non-dimensional slenderness, reduction factor chi, NRd and utilisation. Indicative, not a stamped design.
| Argument | Type | Description |
|---|---|---|
| section | string | Steel section key, e.g. UC203x203x46 (steel only) |
| depth_mm | number | RC column depth h (mm), concrete only |
| material* | string | Section material |
| width_mm | number | RC column width b (mm), concrete only |
| axial_load_kn* | number | Design axial load NEd (kN) |
| buckling_curve | string | EC3 buckling curve (steel only) |
| eccentricity_mm | number | Load eccentricity (mm), optional |
| reinforcement_pct | number | RC reinforcement ratio % (concrete only) |
| effective_length_m* | number | Effective (buckling) length Lcr (m) |
Generate an indicative Technical Due Diligence (TDD) fee estimate. Returns preliminary and full DD fee ranges (GBP), turnaround days, and contact CTA.
| Argument | Type | Description |
|---|---|---|
| geography* | string | |
| disciplines* | array | |
| building_type* | string | office, data_centre, industrial, retail, residential, mixed_use, hotel, warehouse, healthcare |
| gross_area_m2* | number | |
| timeline_weeks* | integer | |
| transaction_type* | string |
{
"type": "object",
"required": [
"building_type",
"gross_area_m2",
"transaction_type",
"disciplines",
"geography",
"timeline_weeks"
],
"properties": {
"geography": {
"enum": [
"uk",
"eu",
"uae",
"gcc"
],
"type": "string"
},
"disciplines": {
"type": "array",
"items": {
"enum": [
"structural",
"mep",
"compliance",
"energy",
"nis2"
],
"type": "string"
}
},
"building_type": {
"type": "string",
"description": "office, data_centre, industrial, retail, residential, mixed_use, hotel, warehouse, healthcare"
},
"gross_area_m2": {
"type": "number"
},
"timeline_weeks": {
"type": "integer"
},
"transaction_type": {
"enum": [
"acquisition",
"disposal",
"refinancing",
"planning"
],
"type": "string"
}
}
}Domestic whole-dwelling fabric + ventilation heat-loss estimate for heat pump sizing (BS EN 12831 / MCS), from floor area, storeys, age band, location and glazing. Returns design heat loss (kW), recommended heat pump output, indicative SCOP and annual demand. Typical U-values/SCOP, not measured.
| Argument | Type | Description |
|---|---|---|
| storeys | integer | |
| age_band* | string | |
| location* | string | |
| flow_temp_c | integer | Emitter flow temperature |
| floor_area_m2* | number | |
| air_change_rate | number | ACH, default 0.5 |
| ceiling_height_m | number | Default 2.4 |
| glazing_pct_of_floor | number | Default 25 |
| external_design_temp_c | number | Override 99.6% external design temp |
| internal_design_temp_c |
England & Wales Minimum Energy Efficiency Standard (MEES) check for private rented property. Tests against the in-force EPC E minimum (domestic and non-domestic) and surfaces the PROPOSED (not yet law) EPC C / 2030 uplift as an advisory only. Returns compliance, can-let, cost cap and penalties.
| Argument | Type | Description |
|---|---|---|
| property_type* | string | |
| current_epc_band* | string |
{
"type": "object",
"required": [
"property_type",
"current_epc_band"
],
"properties": {
"property_type": {
"enum": [
"domestic",
"non_domestic"
],
"type": "string"
},
"current_epc_band": {
"enum": [
"A",
"B",
"C",
"D",
"E",
"F",
"G"
],
"type": "string"
}
}
}UK Approved Document O 2021 simplified-method overheating check for new residential: tests maximum glazing area (by orientation, risk zone, cross vs single aspect) and minimum free ventilation area. Returns pass/fail and points to CIBSE TM59 modelling if it fails. Indicative.
| Argument | Type | Description |
|---|---|---|
| floor_area_m2* | number | |
| location_risk* | string | high = listed London postcode districts (AD O Table C1) |
| glazing_area_m2* | number | |
| cross_ventilation | string | |
| most_glazed_facade* | string | |
| provided_free_area_m2 | number | Total openable free area provided (optional) |
{
"type": "object",
"required": [
"location_risk",
"most_glazed_facade",
"floor_area_m2",
"glazing_area_m2"
],
"properties": {
"floor_area_m2": {
"type": "number"
},
"location_risk": {
"enum": [
"high",
"moderate"
],
"type": "string",
"description": "high = listed London postcode districts (AD O Table C1)"
},
"glazing_area_m2": {
"type": "number"
},
"cross_ventilation": {
"enum": [
"yes",
"no"
],
"type": "string"
},
"most_glazed_facade": {
"enum": [
"N",
"E",
"S",
"W"
],
"type": "string"
},
"provided_free_area_m2": {
"type": "number",
"description": "Total openable free area provided (optional)"
}
}
}UK Approved Document S 2021 electric-vehicle charge-point requirement calculator for new build and major renovation, residential and non-residential. Returns required charge points, cable routes (1-in-5 for non-residential), minimum power and the applicable cost caps/exemptions. Indicative.
| Argument | Type | Description |
|---|---|---|
| works* | string | |
| dwellings | integer | Number of dwellings (residential) |
| building_type* | string | |
| parking_spaces* | integer | Total associated parking spaces |
| covered_car_park | string | Non-residential covered car park? |
{
"type": "object",
"required": [
"building_type",
"works",
"parking_spaces"
],
"properties": {
"works": {
"enum": [
"new",
"major_renovation"
],
"type": "string"
},
"dwellings": {
"type": "integer",
"description": "Number of dwellings (residential)"
},
"building_type": {
"enum": [
"residential",
"non_residential"
],
"type": "string"
},
"parking_spaces": {
"type": "integer",
"description": "Total associated parking spaces"
},
"covered_car_park": {
"enum": [
"yes",
"no"
],
"type": "string",
"description": "Non-residential covered car park?"
}
}
}Engineering ROI calculator. Returns current manual cost, annual saving, net benefit, ROI %, payback months, 3-year NPV and a verdict.
| Argument | Type | Description |
|---|---|---|
| team_size* | number | |
| hourly_rate* | number | |
| manual_hours* | number | manual hours per week |
| software_cost | number | annual GBP (default 0) |
| efficiency_gain_pct* | number | <=90 |
| implementation_time_months* | number |
{
"type": "object",
"required": [
"team_size",
"hourly_rate",
"manual_hours",
"efficiency_gain_pct",
"implementation_time_months"
],
"properties": {
"team_size": {
"type": "number"
},
"hourly_rate": {
"type": "number"
},
"manual_hours": {
"type": "number",
"description": "manual hours per week"
},
"software_cost": {
"type": "number",
"description": "annual GBP (default 0)"
},
"efficiency_gain_pct": {
"type": "number",
"description": "<=90"
},
"implementation_time_months": {
"type": "number"
}
}
}UK SAP 10.3 / SBEM EPC precheck. Maps a known SAP rating (1-100) to its EPC band, and/or computes annual CO2 and primary energy from fuel consumption using validated SAP 10 fuel factors. The official EPC band is cost-based and needs a full SAP/RdSAP assessment.
| Argument | Type | Description |
|---|---|---|
| sap_rating | number | Known SAP rating 1-100 (returns the EPC band) |
| floor_area_m2 | number | For carbon/primary-energy intensity |
| annual_energy_kwh | object | Map fuel -> kWh/yr. Fuels: mains_gas, grid_electricity, heating_oil, lpg, wood_pellets, wood_logs, wood_chips, biomass_community |
{
"type": "object",
"required": [],
"properties": {
"sap_rating": {
"type": "number",
"description": "Known SAP rating 1-100 (returns the EPC band)"
},
"floor_area_m2": {
"type": "number",
"description": "For carbon/primary-energy intensity"
},
"annual_energy_kwh": {
"type": "object",
"description": "Map fuel -> kWh/yr. Fuels: mains_gas, grid_electricity, heating_oil, lpg, wood_pellets, wood_logs, wood_chips, biomass_community"
}
}
}Thermal Load Estimator for data centres / critical facilities. Returns total heat load, cooling capacity, units, airflow, chiller size, PUE estimate, power density, and a CRAC/CRAH/DLC/immersion comparison.
| Argument | Type | Description |
|---|---|---|
| it_load_kw* | number | |
| redundancy* | string | |
| lighting_kw | number | default 5 |
| cooling_type* | string | |
| room_area_m2* | number | |
| ambient_temp_c* | number | |
| ups_efficiency_pct* | number | 1-99.9 |
{
"type": "object",
"required": [
"it_load_kw",
"ups_efficiency_pct",
"room_area_m2",
"cooling_type",
"redundancy",
"ambient_temp_c"
],
"properties": {
"it_load_kw": {
"type": "number"
},
"redundancy": {
"enum": [
"n",
"n1",
"2n"
],
"type": "string"
},
"lighting_kw": {
"type": "number",
"description": "default 5"
},
"cooling_type": {
"enum": [
"crac",
"crah",
"dlc",
"immersion"
],
"type": "string"
},
"room_area_m2": {
"type": "number"
},
"ambient_temp_c": {
"type": "number"
},
"ups_efficiency_pct": {
"type": "number",
"description": "1-99.9"
}
}
}UAE Scope 1 + Scope 2 GHG estimate from electricity and gas use, with emirate-specific grid emission factors (Dubai/Abu Dhabi/national) and the Federal Decree-Law No. 11 of 2024 mandatory-reporting context. Grid factors carry base-year/confidence caveats.
| Argument | Type | Description |
|---|---|---|
| gas_m3 | number | Annual natural gas (m3), alternative to gas_kwh |
| emirate* | string | |
| gas_kwh | number | Annual natural gas (kWh) |
| electricity_kwh* | number | Annual grid electricity (kWh) |
{
"type": "object",
"required": [
"emirate",
"electricity_kwh"
],
"properties": {
"gas_m3": {
"type": "number",
"description": "Annual natural gas (m3), alternative to gas_kwh"
},
"emirate": {
"enum": [
"dubai",
"abu_dhabi",
"national"
],
"type": "string"
},
"gas_kwh": {
"type": "number",
"description": "Annual natural gas (kWh)"
},
"electricity_kwh": {
"type": "number",
"description": "Annual grid electricity (kWh)"
}
}
}UK permitted-development (GPDO 2015, England) rules engine for extensions, loft conversions and change of use. Returns a verdict (likely_pd / requires_permission / complex), applicable PD class, conditions and flags (listed building, Article 4, conservation area, AONB). Indicative, verify with the LPA.
| Argument | Type | Description |
|---|---|---|
| listed | string | |
| location | string | |
| proposal* | string | |
| article_4 | string | |
| use_class | string | Existing use class (C3, C1, E, B2, B8, F1, F2, SG) |
| proposed_use | string | Proposed use class (change of use only); 'same' if unchanged |
| property_type* | string | |
| conservation_area | string | |
| extension_depth_m | number | Rear extension depth (m), for extension proposals |
| national_park_aonb |
{
"type": "object",
"required": [
"building_type",
"floor_area_m2",
"location",
"year_built"
],
"properties": {
"location": {
"enum": [
"uk",
"eu",
"uae"
],
"type": "string"
},
"occupancy": {
"type": "number"
},
"year_built": {
"type": "integer"
},
"refrigerant": {
"enum": [
"hfc",
"hfo",
"none"
],
"type": "string"
},
"gas_kwh_year": {
"type": "number"
},
"building_type": {
"enum": [
"office",
"retail",
"industrial",
"datacentre",
"healthcare",
"education",
"residential"
],
"type": "string"
},
"elec_kwh_year": {
"type": "number"
},
"floor_area_m2": {
"type": "number"
},
"heat_kwh_year": {
"type": "number"
},
"renewable_pct": {
"type": "number"
}
}
}| has_supplier_assessment* |
| boolean |
| has_network_segmentation* | boolean |
{
"type": "object",
"required": [
"has_ciso",
"has_ot_policy",
"has_board_reporting",
"has_asset_inventory",
"has_network_segmentation",
"has_ir_plan",
"has_24h_reporting",
"has_supplier_assessment",
"has_ot_monitoring",
"organisation_size",
"sector"
],
"properties": {
"sector": {
"type": "string",
"description": "e.g. energy, transport, healthcare, banking"
},
"has_ciso": {
"type": "boolean"
},
"has_ir_plan": {
"type": "boolean"
},
"has_ot_policy": {
"type": "boolean"
},
"has_24h_reporting": {
"type": "boolean"
},
"has_ot_monitoring": {
"type": "boolean"
},
"organisation_size": {
"enum": [
"essential",
"important",
"other"
],
"type": "string"
},
"has_asset_inventory": {
"type": "boolean"
},
"has_board_reporting": {
"type": "boolean"
},
"has_supplier_assessment": {
"type": "boolean"
},
"has_network_segmentation": {
"type": "boolean"
}
}
}{
"type": "object",
"required": [
"material",
"config",
"span_m",
"udl_kn_m"
],
"properties": {
"grade": {
"type": "string",
"description": "Steel: s275/s355. Concrete: c2530/c3037/c3545"
},
"config": {
"enum": [
"ss",
"cant",
"cont"
],
"type": "string",
"description": "ss=simply supported, cant=cantilever, cont=continuous 2-span"
},
"span_m": {
"type": "number",
"description": "Span length (m)"
},
"exposure": {
"enum": [
"xc1",
"xc2",
"xc3"
],
"type": "string",
"description": "Concrete exposure class (cover)"
},
"material": {
"enum": [
"steel",
"composite",
"concrete"
],
"type": "string",
"description": "Beam material"
},
"udl_kn_m": {
"type": "number",
"description": "Characteristic uniformly distributed load (kN/m)"
},
"fire_rating": {
"enum": [
"r30",
"r60",
"r90",
"r120"
],
"type": "string",
"description": "Required fire rating"
},
"load_position": {
"type": "number",
"description": "Point-load position as fraction of span 0-1 (default 0.5)"
},
"point_load_kn": {
"type": "number",
"description": "Characteristic point load (kN), optional"
}
}
}{
"type": "object",
"required": [
"axial_load_kn",
"effective_length_m",
"material"
],
"properties": {
"section": {
"type": "string",
"description": "Steel section key, e.g. UC203x203x46 (steel only)"
},
"depth_mm": {
"type": "number",
"description": "RC column depth h (mm), concrete only"
},
"material": {
"enum": [
"S275",
"S355",
"C25",
"C30"
],
"type": "string",
"description": "Section material"
},
"width_mm": {
"type": "number",
"description": "RC column width b (mm), concrete only"
},
"axial_load_kn": {
"type": "number",
"description": "Design axial load NEd (kN)"
},
"buckling_curve": {
"enum": [
"a",
"b",
"c",
"d"
],
"type": "string",
"description": "EC3 buckling curve (steel only)"
},
"eccentricity_mm": {
"type": "number",
"description": "Load eccentricity (mm), optional"
},
"reinforcement_pct": {
"type": "number",
"description": "RC reinforcement ratio % (concrete only)"
},
"effective_length_m": {
"type": "number",
"description": "Effective (buckling) length Lcr (m)"
}
}
}| number |
| Default 21 |
{
"type": "object",
"required": [
"floor_area_m2",
"age_band",
"location"
],
"properties": {
"storeys": {
"type": "integer"
},
"age_band": {
"enum": [
"pre_1900",
"1900_1929",
"1930_1949",
"1950_1966",
"1967_1975",
"1976_1982",
"1983_1990",
"1991_1995",
"1996_2002",
"2003_2006",
"2007_2011",
"2012_2022",
"2023_plus"
],
"type": "string"
},
"location": {
"enum": [
"london",
"birmingham",
"manchester",
"glasgow",
"edinburgh",
"leeds",
"newcastle",
"cardiff",
"belfast",
"plymouth",
"southampton"
],
"type": "string"
},
"flow_temp_c": {
"enum": [
35,
45,
55
],
"type": "integer",
"description": "Emitter flow temperature"
},
"floor_area_m2": {
"type": "number"
},
"air_change_rate": {
"type": "number",
"description": "ACH, default 0.5"
},
"ceiling_height_m": {
"type": "number",
"description": "Default 2.4"
},
"glazing_pct_of_floor": {
"type": "number",
"description": "Default 25"
},
"external_design_temp_c": {
"type": "number",
"description": "Override 99.6% external design temp"
},
"internal_design_temp_c": {
"type": "number",
"description": "Default 21"
}
}
}| string |
{
"type": "object",
"required": [
"property_type",
"proposal"
],
"properties": {
"listed": {
"enum": [
"yes",
"no"
],
"type": "string"
},
"location": {
"enum": [
"england",
"wales",
"scotland",
"ni"
],
"type": "string"
},
"proposal": {
"enum": [
"extension",
"loft",
"outbuilding",
"cou",
"newdwelling",
"subdivision",
"demolition"
],
"type": "string"
},
"article_4": {
"enum": [
"yes",
"no",
"unknown"
],
"type": "string"
},
"use_class": {
"type": "string",
"description": "Existing use class (C3, C1, E, B2, B8, F1, F2, SG)"
},
"proposed_use": {
"type": "string",
"description": "Proposed use class (change of use only); 'same' if unchanged"
},
"property_type": {
"enum": [
"house",
"flat",
"commercial",
"industrial",
"agricultural",
"mixed"
],
"type": "string"
},
"conservation_area": {
"enum": [
"yes",
"no"
],
"type": "string"
},
"extension_depth_m": {
"type": "number",
"description": "Rear extension depth (m), for extension proposals"
},
"national_park_aonb": {
"enum": [
"yes",
"no"
],
"type": "string"
}
}
}